OSHA SearchOSHA records by employer

Eroc Construction Inc: OSHA inspections and violations

New York, New York · Commercial and Institutional Building Construction · NAICS 236220

1inspections
6citation items
$7,560current penalties
Jan 28, 2016last inspection

OSHA has inspected Eroc Construction Inc once in New York.

The inspection began on Jan 28, 2016 as a planned inspection, in New York.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $10,800 and now stand at $7,560, 30% lower after settlements or reviews.

Electrical equipment on job sites comes up most often in these citations: 2 items under 1926.403.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Eroc Construction Inc averages $7,560 (1 cited inspection).

Eroc Construction Inc: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

358employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Eroc Construction Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341224954 OPENED JAN 28, 2016Closed

Planned · Complete · Safety · 4 employees at the site · Closed Apr 10, 2019

78 Bowery St, New York, NY 10002 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$1,200$855Mar 31, 2016Final
Citation 1, item 2
29 CFR 1926.403(b)(1)(i) · Electrical equipment on job sites
Serious$1,600$1,140Mar 31, 2016Final
Citation 1, item 3
29 CFR 1926.403(e) · Electrical equipment on job sites
Serious$1,600$1,140Mar 31, 2016Final
Citation 1, item 4
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Serious$1,600$1,005Mar 31, 2016Final
Citation 1, item 5
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$2,000$1,425Mar 31, 2016Final
Citation 1, item 6
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,800$1,995Mar 31, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)(i)

(i) Suitability for installation and use in conformity with the provisions of this subpart. Suitability of equipment for an identified purpose may be evidenced by listing, labeling, or certification for that identified purpose.

29 CFR 1926.403(e)

(e) Splices. Conductors shall be spliced or joined with splicing devices designed for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be so spliced or joined as to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other commercial and institutional building construction employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.