Inspection 341953446 OPENED DEC 6, 2016Closed
3212 Canada Rd, Painted Post, NY 14870 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Painted Post, New York · Sewage Treatment Facilities · NAICS 221320
Since 1991, OSHA inspectors have visited Erwin TN WWTP in New York 11 times.
The most recent inspection opened on Dec 6, 2016 to follow up on an earlier case, in Painted Post.
In all, OSHA issued 42 citation items: 26 serious and 16 other-than-serious.
No penalty came with these citations.
The rule cited most here is 1910.106 (flammable liquids), 4 times.
Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Erwin TN WWTP averages $0 across 2 cited inspections.
New York · latest 90 days of OSHA records
359employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Erwin TN WWTP and get notified the morning OSHA posts a new citation for it.
Watch this company3212 Canada Rd, Painted Post, NY 14870 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3212 Canada Rd, Painted Post, NY 14870 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3212 Canada Rd, Painted Post, NY 14870 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Oct 26, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Oct 26, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.37(b)(2) · Exit routes |
Serious | $0 | $0 | Oct 26, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.212(b) · Machine guarding |
Serious | $0 | $0 | Oct 26, 2016 | Final |
| Citation 1, item 5 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $0 | $0 | Oct 26, 2016 | Final |
| Citation 1, item 6 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | Oct 26, 2016 | Final |
3212 Canada Rd, Painted Post, NY 14870 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1200(f)(6)(ii) · Hazard communication |
Serious | $0 | $0 | Oct 19, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.134(k)(5) · Respiratory protection |
Other-than-serious | $0 | $0 | Oct 19, 2016 | Final |
3212 Canada Rd, Painted Post, NY 14870 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3212 Canada Rd, Painted Post, NY 14870 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Serious | $0 | $0 | May 20, 2010 | Closed |
| Citation 2, item 1 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | May 20, 2010 | Closed |
| Citation 2, item 2 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | May 20, 2010 | Closed |
| Citation 2, item 3 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | May 20, 2010 | Closed |
3212 Canada Rd, Painted Post, NY 14870 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3212 Canada Rd, Painted Post, NY 14870 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $0 | $0 | Jan 8, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.305(j)(2)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Jan 8, 2003 | Closed |
| Citation 1, item 3 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Serious | $0 | $0 | Jan 8, 2003 | Closed |
| Citation 2, item 1 29 CFR 1910.23(b)(1)(i) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Jan 8, 2003 | Closed |
| Citation 2, item 2 29 CFR 1910.146(c)(1) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Jan 8, 2003 | Closed |
| Citation 2, item 3 29 CFR 1910.146(d)(2) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Jan 8, 2003 | Closed |
| Citation 2, item 4 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jan 8, 2003 | Closed |
| Citation 2, item 5 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 8, 2003 | Closed |
| Citation 2, item 6 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 8, 2003 | Closed |
3212 Canada Rd, Painted Post, NY 14870 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3212 Canada Rd, Painted Post, NY 14870 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3212 Canada Rd, Painted Post, NY 14870 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(c) · General requirements |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 2 29 CFR 1910.106(b)(3)(iva) · Flammable liquids |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 3 29 CFR 1910.106(b)(3)(iii) · Flammable liquids |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 4 29 CFR 1910.106(g)(3)(ivd) · Flammable liquids |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 5 29 CFR 1910.106(g)(9) · Flammable liquids |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 6 29 CFR 1910.141(b)(2)(i) · Sanitation |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 7 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 8 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 9 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 10 29 CFR 1910.219(c)(3) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 11 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 12 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 13 29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 14 29 CFR 1910.307(b) · Hazardous (classified) locations |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 1, item 15 29 CFR 3A0001 |
Serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 2, item 1 29 CFR 1910.22(a)(1) · General requirements |
Other-than-serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 2, item 2 29 CFR 1910.134(a)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 2, item 3 29 CFR 1910.151(b) · First aid and eyewash |
Other-than-serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 2, item 4 29 CFR 1910.157(c)(10) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 2, item 5 29 CFR 1910.304(f)(5)(vc) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jun 3, 1991 | Closed |
| Citation 2, item 6 29 CFR 1926.1000(b) · Rollover Protective Structures; Overhead Protection: scope |
Other-than-serious | $0 | $0 | Jun 3, 1991 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(g)(3)(ivd)
(iv) Dispensing units. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be transferred from tanks by means of fixed pumps so designed and equipped as to allow control of the flow and to prevent leakage or accidental discharge.
29 CFR 1910.106(g)(9)
(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.