OSHA SearchOSHA records by employer

Eurocustomspr Corp: OSHA inspections and violations

Caguas, Puerto Rico · Automotive Exhaust System Repair · NAICS 811112

1inspections
5citation items
$900current penalties
Jul 14, 2016last inspection

OSHA inspectors have visited Eurocustomspr Corp in Puerto Rico one time.

It opened on Jul 14, 2016, in Caguas.

In all, OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

The penalties, $900 in total, stand where OSHA first set them.

The rule cited most here is 1910.253 (gas welding and cutting), 2 times.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Eurocustomspr Corp averages $900 across 1 cited inspection.

Eurocustomspr Corp: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

109employers cited

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch Eurocustomspr Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341619336 OPENED JUL 14, 2016Closed

Programmed other · Partial · Safety · 4 employees at the site · Closed Jan 25, 2017

Carr 1 Km 33.3, Caguas, PR 00725 · Automotive Exhaust System Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 6 A
Serious$300$300Dec 27, 2016Final
Citation 1, item 2
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$300$300Dec 27, 2016Final
Citation 1, item 3
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$300$300Dec 27, 2016Final
Citation 2, item 1
29 CFR 17 IV A 1
Other-than-serious$0$0Dec 27, 2016Final
Citation 2, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Dec 27, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(2)(ii)

(ii) Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.

29 CFR 1910.253(b)(2)(iv)

(iv) Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.

Other automotive exhaust system repair employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.