OSHA SearchOSHA records by employer

Eurokera North America Inc: OSHA inspections and violations

Fountain Inn, South Carolina · Glass Product Manufacturing Made of Purchased Glass · NAICS 327215

1inspections
7citation items
$1,712current penalties
Nov 29, 2016last inspection

Eurokera North America Inc has one OSHA inspection on record in South Carolina.

OSHA opened it on Nov 29, 2016 as a planned inspection, in Fountain Inn.

From that inspection OSHA issued 7 citation items: 7 serious.

OSHA proposed $5,450 in penalties. After settlements and reviews the total is $1,712, down 69%.

Most often, OSHA cited 1910.212, machine guarding (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Eurokera North America Inc averages $1,712 over 1 cited inspection in that time.

Eurokera North America Inc also files yearly injury logs with OSHA, summarized below.

Eurokera North America Inc: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

40employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Eurokera North America Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341951606 OPENED NOV 29, 2016Closed

Planned · Complete · Safety · 150 employees at the site · Closed Jun 6, 2017

140 Southchase Blvd, Fountain Inn, SC 29644 · Glass Product Manufacturing Made of Purchased Glass · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.137(c)(2)(viii) · Electrical protective equipment
Serious$1,000$500Mar 1, 2017Final
Citation 1, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$600$300Mar 1, 2017Final
Citation 1, item 8a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,000$500Mar 1, 2017Final
Citation 1, item 8b
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$825$0Mar 1, 2017Final
Citation 1, item 8c
29 CFR 1910.212(a)(5) · Machine guarding
Serious$600$0Mar 1, 2017Final
Citation 1, item 9a
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$825$412Mar 1, 2017Final
Citation 1, item 9b
29 CFR 1910.334(a)(3)(i) · Using electrical equipment
Serious$600$0Mar 1, 2017Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Fountain Inn site logged 1 recordable injury or illness among about 115 workers: 0.9 per 100 full-time workers, against a median of 3.1 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
EuroKera North America, Inc.
Fountain Inn · 2025
115 100.93.1
EuroKera North America
Fountain Inn · 2021
124 503.53.1

Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.137 · Electrical protective equipment

29 CFR 1910.137(c)(2)(viii)

(viii) Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-4 and Table I-5.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.334 · Using electrical equipment

Other glass product manufacturing made of purchased glass employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.