OSHA SearchOSHA records by employer

Evelyn Baird Gentry Corporation: OSHA inspections and violations

The Woodlands, Texas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
2citation items
$7,989current penalties
Apr 15, 2026last inspection

Evelyn Baird Gentry Corporation has 3 OSHA inspections on record in Texas, the first in 2016.

OSHA's last visit started on Apr 15, 2026 as part of a related case, in Houston.

Across those inspections OSHA issued 2 citation items: 2 serious.

OSHA proposed $13,315 in penalties. After settlements and reviews the total is $7,989, down 40%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Evelyn Baird Gentry Corporation averages $3,994 over 2 cited inspections in that time.

It reported 2 severe injuries to OSHA since 2015.

Evelyn Baird Gentry Corporation: OSHA citation items per year, 2016 to 2026
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

403employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Evelyn Baird Gentry Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348878141 OPENED APR 15, 2026Closed

Unprogrammed related · Partial · Safety · 60 employees at the site · Closed Oct 7, 2026

7200 Cambridge St, Houston, TX 77030 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343382909 OPENED AUG 13, 2018Closed

Unprogrammed other · Partial · Safety · 200 employees at the site · Closed Oct 26, 2018

8060 Spencer Hwy, Pasadena, TX 77505 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$8,315$4,989Oct 2, 2018Final

Inspection 341221679 OPENED FEB 2, 2016Closed

Complaint · Partial · Health · 110 employees at the site · Closed Mar 2, 2016

17201 I-45 South, The Woodlands, TX 77385 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$5,000$3,000Feb 12, 2016Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Nov 6, 2025, Houston: Hospitalization · injuries to internal organs, major blood vessels unspecified · abdomen unspecified

An employee was operating a pipe threading machine and threading a 6-inch conduit pipe on the machine. The clamp that holds the threader on the machine came loose while he was releasing the pipe, causing the pipe to pop back and strike him in the stomach. The employee was hospitalized with blunt force trauma to the stomach.

Oct 10, 2024, Houston: Hospitalization · fractures · forearm(s)

An electrician was working from a 10-foot ladder, reaching up to place an I-beam and conduit. He fell backward from the ladder, landing 8 feet below on the concrete floor and suffering a closed displaced transverse fracture of the shaft of his left radius.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

Other electrical contractors and other wiring installation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.