OSHA SearchOSHA records by employer

Everson Tesla, Inc.: OSHA inspections and violations

Nazareth, Pennsylvania · Motor and Generator Manufacturing · NAICS 335312

3inspections
26citation items
$27,961current penalties
Oct 15, 2024last inspection

Since 2011, OSHA inspectors have visited Everson Tesla, Inc. in Pennsylvania 3 times.

The most recent inspection opened on Oct 15, 2024 after a complaint, in Nazareth.

In all, OSHA issued 26 citation items: 26 serious.

The proposed penalties came to $38,101; today they stand at $27,961, 27% less.

The rule cited most here is 1910.146 (permit-required confined spaces), 19 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Everson Tesla, Inc. averages $21,101 across 1 cited inspection.

Everson Tesla, Inc. also files yearly injury logs with OSHA, summarized below.

Everson Tesla, Inc.: OSHA citation items per year, 2011 to 2024
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Everson Tesla, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347815524 OPENED OCT 15, 2024Closed

Complaint · Partial · Health · 98 employees at the site · Closed Apr 8, 2025

614 Gremar Rd, Nazareth, PA 18064 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340787944 OPENED JUL 16, 2015Closed

Referral · Partial · Health · 73 employees at the site · Closed Mar 17, 2016

614 Gremar Rd, Nazareth, PA 18064 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.106(e)(2)(iv)(d) · Flammable liquids
Serious$3,273$2,166Dec 1, 2015Final
Citation 1, item 3a
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$5,390$3,773Dec 1, 2015Final
Citation 1, item 3b
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 3c
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 4a
29 CFR 1910.146(d)(1) · Permit-required confined spaces
Serious$3,273$2,166Dec 1, 2015Final
Citation 1, item 4b
29 CFR 1910.146(d)(2) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 5a
29 CFR 1910.146(d)(3)(i) · Permit-required confined spaces
Serious$0$2,166Dec 1, 2015Final
Citation 1, item 5b
29 CFR 1910.146(d)(3)(iii) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 5c
29 CFR 1910.146(d)(3)(vi) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 6a
29 CFR 1910.146(d)(4) · Permit-required confined spaces
Serious$3,273$2,166Dec 1, 2015Final
Citation 1, item 6b
29 CFR 1910.146(d)(5) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 6c
29 CFR 1910.146(d)(6) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 6d
29 CFR 1910.146(d)(8) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 6e
29 CFR 1910.146(d)(9) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 6f
29 CFR 1910.146(d)(10) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 7
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$3,273$2,166Dec 1, 2015Final
Citation 1, item 8
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$3,273$2,166Dec 1, 2015Final
Citation 1, item 9a
29 CFR 1910.146(k)(1)(i) · Permit-required confined spaces
Serious$3,273$2,166Dec 1, 2015Final
Citation 1, item 9b
29 CFR 1910.146(k)(1)(ii) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 9c
29 CFR 1910.146(k)(1)(v) · Permit-required confined spaces
Serious$0$0Dec 1, 2015Final
Citation 1, item 10a Serious$3,273$2,166Dec 1, 2015Final
Citation 1, item 10b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Dec 1, 2015Final

Inspection 314726860 OPENED OCT 26, 2011Closed

Complaint · Partial · Health · 80 employees at the site · Closed May 14, 2013

615 Daniels Road, Nazareth, PA 18067 · Industrial Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$2,100$1,470Jan 24, 2012Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$4,900$3,430Jan 24, 2012Closed
Citation 1, item 3a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,800$1,960Jan 24, 2012Closed
Citation 1, item 3b
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Jan 24, 2012Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Nazareth site logged 4 recordable injuries or illnesses among about 102 workers: 3.6 per 100 full-time workers, against a median of 1.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Everson Tesla Inc.
Nazareth · 2025
102 403.61.4
Everson Tesla, Incorporated
Nazareth · 2018
92 405.01.4

Included with any plan: 4 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(iv)(d)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(1)

(c) General requirements. (1) The employer shall evaluate the workplace to determine if any spaces are permit- required confined spaces.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other motor and generator manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.