Excel One Electric, Inc.: OSHA inspections and violations

Houston, Texas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
4citation items
$5,650current penalties
Apr 4, 2016last inspection

Since 1999, OSHA inspectors have visited Excel One Electric, Inc. in Texas 4 times.

The most recent inspection opened on Apr 4, 2016, in Katy.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $6,400; today they stand at $5,650, 12% less.

The rule cited most here is 1926.405 (job-site wiring), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Excel One Electric, Inc. averages $4,900 across 1 cited inspection.

Excel One Electric, Inc.: OSHA citation items per year, 1999 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Excel One Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341374155 OPENED APR 4, 2016Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Aug 9, 2016

20801 Highland Knolls Dr, Katy, TX 77450 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$4,900$4,900Jul 1, 2016Final
Citation 1, item 2b
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$0$0Jul 1, 2016Final
Citation 1, item 3c
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$0$0Jul 1, 2016Final

Inspection 339890246 OPENED AUG 5, 2014Closed

Unprogrammed other · Complete · Safety · 13 employees at the site · Closed Nov 24, 2014

13411 Briar Forest Drive, Houston, TX 77077 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 123627473 OPENED MAY 24, 2000Closed

Unprogrammed other · Complete · Health · 6 employees at the site · Closed May 24, 2000

401 W.pasadena Blvd., Deer Park, TX 77536 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 123618829 OPENED APR 22, 1999Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Jun 17, 1999

7550 Kirby Drive, Houston, TX 77030 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(iib) · Job-site wiring
Serious$1,500$750May 19, 1999Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(iib)

(B) Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices at their ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.