OSHA SearchOSHA records by employer

Excellent Interior Inc.: OSHA inspections and violations

Brooklyn, New York · All Other Specialty Trade Contractors · NAICS 238990

5inspections
8citation items
$65,123current penalties
Aug 4, 2026last inspection

Excellent Interior Inc. has 5 OSHA inspections on record in New York, the first in 2019.

OSHA's last visit started on Aug 4, 2026 to follow up on an earlier case, in Brooklyn.

Across those inspections OSHA issued 8 citation items: 8 serious.

OSHA proposed $65,123 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.502, fall protection systems (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Excellent Interior Inc. averages $32,562 over 2 cited inspections in that time.

Excellent Interior Inc.: OSHA citation items per year, 2019 to 2026
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

350employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Excellent Interior Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349090423 OPENED AUG 4, 2026Closed

Follow-up · Partial · Safety · 2 employees at the site · Closed Nov 6, 2026

2304 Bedford Ave, Brooklyn, NY 11226 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347553836 OPENED JUN 14, 2024Open

Unprogrammed other · Partial · Safety · 2 employees at the site · Open

2304 Bedford Avenue, Brooklyn, NY 11226 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$7,098$7,098Dec 12, 2024Final

Inspection 346149131 OPENED AUG 16, 2022Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Jan 5, 2023

128 Montrose Avenue, Brooklyn, NY 11206 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345305338 OPENED MAY 13, 2021Closed

Planned · Complete · Safety · 11 employees at the site · Closed Jul 2, 2021

816 Quentin Rd 1702 E. 9th St Corner Bldg, Brooklyn, NY 11223 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344420153 OPENED NOV 1, 2019Closed

Complaint · Partial · Safety · 11 employees at the site · Closed Sep 4, 2026

475 Grand Street, Brooklyn, NY 11211 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$6,747$6,747Apr 28, 2020Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$9,446$9,446Apr 28, 2020Final
Citation 1, item 3
29 CFR 1926.502(d)(5) · Fall protection systems
Serious$9,446$9,446Apr 28, 2020Final
Citation 1, item 4
29 CFR 1926.502(d)(6)(i) · Fall protection systems
Serious$9,446$9,446Apr 28, 2020Final
Citation 1, item 5
29 CFR 1926.760(a)(1) · Fall protection
Serious$9,446$9,446Apr 28, 2020Final
Citation 1, item 6
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$6,747$6,747Apr 28, 2020Final
Citation 1, item 7
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$6,747$6,747Apr 28, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1052(c)(12)

(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.760 · Fall protection

Other all other specialty trade contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.