Roseville, Michigan · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · NAICS 332722

2inspections
18citation items
$2,550current penalties
Aug 16, 2019last inspection

OSHA has inspected Exotic Fasteners Inc 2 times in Michigan since 2016.

The latest one began on Aug 16, 2019 as a planned inspection, in Roseville.

Those inspections ended with 18 citation items: 9 serious and 9 other-than-serious.

Penalties were first proposed at $5,100 and now stand at $2,550, 50% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Exotic Fasteners Inc averages $1,275 (2 cited inspections).

Exotic Fasteners Inc also files yearly injury logs with OSHA, summarized below.

Exotic Fasteners Inc: OSHA citation items per year, 2016 to 2019
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

656employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Exotic Fasteners Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344238860 OPENED AUG 16, 2019Closed

Planned · Complete · Safety · 19 employees at the site · Closed Nov 26, 2019

15281 E 12 Mile Rd, Roseville, MI 48066 · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10716
Serious$600$300Sep 17, 2019Final
Citation 1, item 2
29 CFR 408.10722(1)
Serious$800$400Sep 17, 2019Final
Citation 1, item 3
29 CFR 408.10731(1)
Serious$1,000$500Sep 17, 2019Final
Citation 1, item 4
29 CFR 408.11442(2)
Serious$800$400Sep 17, 2019Final
Citation 2, item 1
29 CFR 408.10645(2)
Other-than-serious$0$0Sep 17, 2019Final
Citation 2, item 2
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$0$0Sep 17, 2019Final

Inspection 340208628 OPENED OCT 20, 2016Closed

Planned · Complete · Safety · 23 employees at the site · Closed Dec 27, 2016

15281 E 12 Mile Rd, Roseville, MI 48066 · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10213(2)
Serious$400$200Nov 30, 2016Final
Citation 1, item 2
29 CFR 408.10034(9)
Serious$300$150Nov 30, 2016Final
Citation 1, item 3
29 CFR 408.12632(1)
Serious$400$200Nov 30, 2016Final
Citation 1, item 4
29 CFR 408.12649(2)
Serious$400$200Nov 30, 2016Final
Citation 1, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$400$200Nov 30, 2016Final
Citation 2, item 1
29 CFR 408.10187(1)
Other-than-serious$0$0Nov 30, 2016Final
Citation 2, item 2
29 CFR 408.11222(6)
Other-than-serious$0$0Nov 30, 2016Final
Citation 2, item 3
29 CFR 408.11223(1)
Other-than-serious$0$0Nov 30, 2016Final
Citation 2, item 4
29 CFR 408.12154(1)
Other-than-serious$0$0Nov 30, 2016Final
Citation 2, item 5
29 CFR 408.12648(1)
Other-than-serious$0$0Nov 30, 2016Final
Citation 2, item 6
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Nov 30, 2016Final
Citation 2, item 7
29 CFR 408.14965(1)
Other-than-serious$0$0Nov 30, 2016Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2019, the Roseville site logged 4 recordable injuries or illnesses among about 22 workers: 21.5 per 100 full-time workers, against a median of 2.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Exotic Fasteners
Roseville · 2019
22 4021.52.7

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)

(6) Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either:

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(2)(i)

(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.