OSHA SearchOSHA records by employer

Exterior Enhancements, LLC: OSHA inspections and violations

Camden Wyoming, Delaware · Siding Contractors · NAICS 238170

1inspections
3citation items
$4,915current penalties
Mar 10, 2021last inspection

OSHA has inspected Exterior Enhancements, LLC once in Delaware.

The inspection began on Mar 10, 2021, in Camden Wyoming.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $8,192 and now stand at $4,915, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Exterior Enhancements, LLC averages $4,915 (1 cited inspection).

Exterior Enhancements, LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Delaware · latest 90 days of OSHA records

33employers cited

Get notified the morning OSHA posts each new citation in Delaware: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Delaware

Checking a subcontractor, a client or your own company? Watch Exterior Enhancements, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345189344 OPENED MAR 10, 2021Closed

Unprogrammed other · Partial · Safety · 10 employees at the site · Closed Oct 6, 2026

33 & 37 Tyndall Trail Tidbury Crossing Development, Camden Wyoming, DE 19934 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(8) · Scaffolds, general requirements
Serious$4,096$2,458Aug 26, 2021Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$4,096$2,458Aug 26, 2021Final
Citation 1, item 2b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Aug 26, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(8)

(8) Direct access to or from another surface shall be used only when the scaffold is not more than 14 inches (36 cm) horizontally and not more than 24 inches (61 cm) vertically from the other surface.

29 CFR 1926.451(g)(1)(v)

(v) Each employee on a walkway located within a scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) installed within 9 1/2 inches (24.1 cm) of and along at least one side of the walkway.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

Other siding contractors employers in Delaware

Alert subscribers get notified of each newly cited employer in Delaware the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.