OSHA SearchOSHA records by employer

Exterior Walls, Inc.: OSHA inspections and violations

Orlando, Florida · Drywall and Insulation Contractors · NAICS 238310

7inspections
11citation items
$17,825current penalties
Mar 23, 2016last inspection

OSHA has inspected Exterior Walls, Inc. 7 times in Florida since 2003.

The latest one began on Mar 23, 2016, in Sarasota.

Those inspections ended with 11 citation items: 9 serious, 1 repeat and 1 other-than-serious.

Penalties were first proposed at $22,700 and now stand at $17,825, 21% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 10 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Exterior Walls, Inc. averages $1,400 (2 cited inspections).

Exterior Walls, Inc.: OSHA citation items per year, 2003 to 2016
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Exterior Walls, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341348084 OPENED MAR 23, 2016Closed

Unprogrammed other · Complete · Safety · 19 employees at the site · Closed Jun 2, 2016

800 Cocoanut Ave., Sarasota, FL 34236 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Other-than-serious$0$0Mar 29, 2016Final

Inspection 340415926 OPENED FEB 4, 2015Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 24, 2026

668 N. Orange Ave, Orlando, FL 32801 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,800$2,800Mar 9, 2015Final

Inspection 340021963 OPENED OCT 20, 2014Closed

Unprogrammed other · Partial · Safety · 10 employees at the site · Closed Oct 14, 2015

1101 N Mills Ave, Orlando, FL 32803 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1)(i) · Scaffolds, general requirements
Serious$2,800$2,800Oct 27, 2014Final

Inspection 313879280 OPENED OCT 18, 2010Closed

Planned · Complete · Safety · 5 employees at the site · Closed Nov 8, 2010

14 Bia Deluna Drive, Pensacola Beach, FL 32561 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307994244 OPENED AUG 2, 2004Closed

Complaint · Complete · Safety · 7 employees at the site · Closed Aug 4, 2004

10234 Us Highway 441/lake Nissan Dealership, Leesburg, FL 34748 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307293282 OPENED MAR 23, 2004Closed

Unprogrammed other · Complete · Safety · 12 employees at the site · Closed Apr 21, 2006

2957 Vineland Rd., Kissimmee, FL 34746 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,800$1,400May 5, 2004Final
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0May 5, 2004Final
Citation 1, item 3
29 CFR 1926.454(a) · Scaffold training
Serious$2,800$1,400May 5, 2004Final
Citation 1, item 4a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$2,800May 5, 2004Final
Citation 1, item 4b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0May 5, 2004Final
Citation 2, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$8,000$4,000May 5, 2004Final

Inspection 306686288 OPENED APR 28, 2003Closed

Planned · Complete · Safety · 3 employees at the site · Closed Sep 17, 2003

8967 International Dr, Orlando, FL 32819 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,750$1,312May 23, 2003Closed
Citation 1, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,750$1,312May 23, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(1)(i)

(i) Guys, ties, and braces shall be installed at locations where horizontal members support both inner and outer legs.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.454 · Scaffold training

Other drywall and insulation contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.