OSHA SearchOSHA records by employer

F and L Siding Construction: OSHA inspections and violations

Charlotte, North Carolina · Siding Contractors · NAICS 238170

1inspections
10citation items
$13,250current penalties
Feb 12, 2018last inspection

F and L Siding Construction has one OSHA inspection on record in North Carolina.

OSHA opened it on Feb 12, 2018 as a planned inspection, in Charlotte.

From that inspection OSHA issued 10 citation items: 9 serious and 1 other-than-serious.

OSHA proposed $20,250 in penalties. After settlements and reviews the total is $13,250, down 35%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. F and L Siding Construction averages $13,250 over 1 cited inspection in that time.

F and L Siding Construction: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

14 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch F and L Siding Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342948908 OPENED FEB 12, 2018Closed

Planned · Partial · Safety · 10 employees at the site · Closed Jul 3, 2023

2908 Grand Union Way, Charlotte, NC 28217 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,500$500Mar 2, 2018Final
Citation 1, item 2
29 CFR 1926.304(d) · Woodworking tools
Serious$1,500$500Mar 2, 2018Final
Citation 1, item 3
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,800$2,000Mar 2, 2018Final
Citation 1, item 4
29 CFR 1926.405(j)(2)(ii) · Job-site wiring
Serious$2,800$2,000Mar 2, 2018Final
Citation 1, item 5
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$2,800$2,000Mar 2, 2018Final
Citation 1, item 6
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$2,800$2,000Mar 2, 2018Final
Citation 1, item 7a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,800$2,000Mar 2, 2018Final
Citation 1, item 7b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Mar 2, 2018Final
Citation 1, item 8
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,800$2,000Mar 2, 2018Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$450$250Mar 2, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(d)

(d) Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.503 · Fall protection training in construction