OSHA SearchOSHA records by employer

F.B.W. Group, Inc.: OSHA inspections and violations

Miami Beach, Florida · New Housing For-Sale Builders · NAICS 236117

2inspections
3citation items
$9,011current penalties
Mar 24, 2016last inspection

F.B.W. Group, Inc. has 2 OSHA inspections on record in Florida, the first in 2014.

OSHA's last visit started on Mar 24, 2016 as part of a related case, in Miami Beach.

Across those inspections OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $9,011 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. F.B.W. Group, Inc. averages $4,811 over 1 cited inspection in that time.

F.B.W. Group, Inc.: OSHA citation items per year, 2014 to 2016
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch F.B.W. Group, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341349884 OPENED MAR 24, 2016Closed

Unprogrammed related · Partial · Safety · 189 employees at the site · Closed Jun 25, 2020

4701 Meridian Ave., Miami Beach, FL 33140 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$4,811$4,811Sep 12, 2016Final
Citation 2, item 1
29 CFR 1926.502(i)(4) · Fall protection systems
Other-than-serious$0$0Sep 12, 2016Final

Inspection 340115716 OPENED DEC 3, 2014Closed

Referral · Partial · Safety · 92 employees at the site · Closed Sep 22, 2015

6620 Indian Trace Dr., Miami Beach, FL 33139 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(3) · Fall protection in construction
Serious$4,200$4,200May 14, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(3)

(3) Hoist areas. Each employee in a hoist area shall be protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems or personal fall arrest systems. If guardrail systems, [or chain, gate, or guardrail] or portions thereof, are removed to facilitate the hoisting operation (e.g., during landing of materials), and an employee must lean through the access opening or out over the edge of the access opening (to receive or guide equipment and materials, for example), that employee shall be protected from fall hazards by a personal fall arrest system.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(i)(4)

(4) All covers shall be color coded or they shall be marked with the word “HOLE” or “COVER” to provide warning of the hazard.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(b)

(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.