Fairley Construction: OSHA inspections and violations

Petal, Mississippi · Framing Contractors · NAICS 238130

1inspections
5citation items
$7,762current penalties
Nov 7, 2016last inspection

OSHA has inspected Fairley Construction once in Mississippi.

The inspection began on Nov 7, 2016 after a complaint, in Petal.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $15,523 and now stand at $7,762, 50% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 4 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Fairley Construction averages $7,762 (1 cited inspection).

Fairley Construction: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Fairley Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341915247 OPENED NOV 7, 2016Closed

Complaint · Complete · Safety · 20 employees at the site · Closed Feb 1, 2018

1272 Evelyn Gandy Parkway, Petal, MS 39465 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$4,490$1,796Jan 5, 2017Final
Citation 1, item 2
29 CFR 1926.405(a)(2)(ii)(a) · Job-site wiring
Serious$2,181$1,418Jan 5, 2017Final
Citation 1, item 3
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$2,726$1,770Jan 5, 2017Final
Citation 1, item 4
29 CFR 1926.405(e)(1) · Job-site wiring
Serious$1,636$980Jan 5, 2017Final
Citation 1, item 5
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$4,490$1,796Jan 5, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(a)

(ii) General requirements for temporary wiring. (A) Feeders shall originate in a distribution center. The conductors shall be run as multiconductor cord or cable assemblies or within raceways; or, where not subject to physical damage, they may be run as open conductors on insulators not more than 10 feet (3.05 m) apart.

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

Other framing contractors employers in Mississippi

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.