OSHA SearchOSHA records by employer

Faith Home Improvements LLC: OSHA inspections and violations

Louisville, Kentucky · Roofing Contractors · NAICS 238160

1inspections
5citation items
$10,500current penalties
Jul 27, 2023last inspection

OSHA inspectors have visited Faith Home Improvements LLC in Kentucky one time.

It opened on Jul 27, 2023 as a planned inspection, in Louisville and is still open.

In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

The penalties, $10,500 in total, stand where OSHA first set them.

The rule cited most here is 1926.1053 (ladders in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Faith Home Improvements LLC averages $10,500 across 1 cited inspection.

Faith Home Improvements LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

191employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Faith Home Improvements LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346864978 OPENED JUL 27, 2023Open

Planned · Partial · Safety · 7 employees at the site · Open

4163 Roosevelt Avenue, Louisville, KY 40213 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$3,500$3,500Jan 10, 2024Contested
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$3,500$3,500Jan 10, 2024Contested
Citation 1, item 3a
29 CFR 1926.1053(b)(15) · Ladders in construction
Serious$3,500$3,500Jan 10, 2024Contested
Citation 1, item 3b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Jan 10, 2024Contested
Citation 2, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$0$0Jan 10, 2024Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(15)

(15) Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.