OSHA SearchOSHA records by employer

Farmers Grain Terminal, Inc.: OSHA inspections and violations

Greenville, Mississippi · General Warehousing and Storage · NAICS 493110

9inspections
14citation items
$22,536current penalties
Nov 16, 2023last inspection

Farmers Grain Terminal, Inc. has 9 OSHA inspections on record in Mississippi, the first in 1975.

OSHA's last visit started on Nov 16, 2023 as a planned inspection, in Greenville.

Across those inspections OSHA issued 14 citation items: 8 serious and 6 other-than-serious.

OSHA proposed $35,276 in penalties. After settlements and reviews the total is $22,536, down 36%.

Most often, OSHA cited 1910.272, grain handling facilities (3 items).

For context, across all transportation and warehousing employers the median penalty per cited inspection since 2015 is $3,560. Farmers Grain Terminal, Inc. averages $7,693 over 2 cited inspections in that time.

2 inspections on this page followed a fatal incident.

Farmers Grain Terminal, Inc. also files yearly injury logs with OSHA, summarized below.

Farmers Grain Terminal, Inc.: OSHA citation items per year, 1975 to 2023
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

24employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Farmers Grain Terminal, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347110801 OPENED NOV 16, 2023Closed

Planned · Complete · Health · 55 employees at the site · Closed Mar 27, 2024

1977 Harbor Front Road Harbor Front Industrial Park, Greenville, MS 38701 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347111957 OPENED NOV 16, 2023Closed

Planned · Complete · Safety · 55 employees at the site · Closed Mar 27, 2024

1977 Harbor Front Road Harbor Front Industrial Park, Greenville, MS 38701 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.242(b) · Hand and power tools
Serious$6,026$6,026Dec 13, 2023Final
Citation 2, item 1
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Dec 13, 2023Final

Inspection 344319801 OPENED SEP 18, 2019Closed

Complaint · Partial · Safety · 50 employees at the site · Closed Apr 2, 2020

1977 Harbor Front Road Harbor Front Industrial Park, Greenville, MS 38701 · Grain and Field Bean Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$6,747$4,048Mar 13, 2020Final
Citation 1, item 1b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Mar 13, 2020Final
Citation 1, item 2
29 CFR 1910.272(j)(1) · Grain handling facilities
Serious$8,096$4,858Mar 13, 2020Final
Citation 2, item 1
29 CFR 1910.272(d) · Grain handling facilities
Other-than-serious$757$454Mar 13, 2020Final

Inspection 107091811 OPENED APR 30, 1998Closed

Accident · Partial · Safety · 30 employees at the site · Closed Jul 11, 1998

Harbor Front Industrial Park, Grenville, MS 38701 · OSHA's record · Phone and website on Google Maps

Incident on Apr 29, 1998 (fatal): Electric shock - ground fault in electric cord

Two employees were working together to empty corn from a 125,000-bushel, round, metal grain storage bin. A sweep auger was in the bottom of bin to extract the g rain (corn). One of the employees had just climbed a 4.5-meter ladder mounted on the outside of the bin to an elevated platform. The platform provided access to the larger of two square bin openings and to a 480-volt motor controller. The e mployees had earlier run a flexible cord from the 480-volt, 7.5-horsepower, thre e-phase drive motor for the auger, which was located inside the bin, to the moto r controller, which was mounted outside. The employee on the platform reconnecte d the plug on the motor's power supply cord into a cord connector extending from the bottom of the motor controller box and resumed pulling corn out of the bott om of the bin. His coworker had positioned himself at the lowest bin opening, wh ich measured 480 by 480 millimeters. These two openings were separated by a bin stiffener and by distances of 1.1 meters horizontally and at least 3.6 meters ve rtically. The lower employee was standing on a short 910-millimeter ladder, lean ing over the opening with his head and shoulders inside the bin so that he could look inside. He yelled up to the other employee, asking him to swing over the a uxiliary pendent control. This was a yellow, Square D pushbutton control (type B W75Y, Series C) connected by a 5.9-meter-long cord (type SJ, three-conductor, AW G No. 16). The lower employee offered to operate the bin's auger from the bottom bin opening until quitting time to allow his coworker a chance to come down fro m the elevated platform. The employee on the platform swung the cord toward the lower employee, who was electrocuted when he grabbed the cord with his left hand .

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$4,500$4,000Jun 18, 1998Closed
Citation 1, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$4,500$2,000Jun 18, 1998Closed
Citation 1, item 3
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$4,500$1,000Jun 18, 1998Closed

Inspection 106309255 OPENED OCT 31, 1989Closed

Accident · Complete · Safety · 35 employees at the site · Closed Dec 8, 1989

Harbor Front Industrial Park, Grenville, MS 38701 · OSHA's record · Phone and website on Google Maps

Incident on Oct 27, 1989 (fatal): Employee suffocated in grain handling faciltiy

At 1:05 p.m. on October 27, 1989, Employee #1 was working in a sorting and stora ge facility at a grain terminal. Employee #1 was breaking up corn screen bridges and cakes with a steel pipe to allow the free flow of grain. Employee #1 was ac cessing the area through a porthole in the side of grain storage and sorting are a. Employee #1 crawled into the opening up to his waste. The corn screenings cav ed-in, fatally suffocating the employee.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$150$150Nov 21, 1989Closed
Citation 1, item 2
29 CFR 1910.106(g)(8) · Flammable liquids
Other-than-serious$0$0Nov 21, 1989Closed
Citation 2, item 1
29 CFR 1904.8 · Recording criteria for needlestick and sharps injuries
Other-than-serious$0$0Nov 21, 1989Closed
Citation 2, item 3
29 CFR 1910.272(g)(6) · Grain handling facilities
Other-than-serious$0$0Nov 21, 1989Closed
Citation 2, item 4
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Nov 21, 1989Closed

Inspection 101557734 OPENED AUG 20, 1986Closed

Planned · No inspection · Safety · Closed Aug 29, 1986

Highway 49 South, Inverness, MS 38753 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 100372424 OPENED MAY 6, 1986Closed

Planned · No inspection · Safety · Closed May 19, 1986

Harber Front Industrial, Greenville, MS 38701 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 1966894 OPENED SEP 16, 1985Closed

Planned · No inspection · Safety · 6 employees at the site · Closed Sep 16, 1985

Hwy. 49 E., North, Webb, MS 38966 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

1 older inspection

Inspection 13547039 OPENED AUG 28, 1975Closed

Planned · Complete · Safety · 13 employees at the site · Closed Mar 10, 1984

Harbor Front Industrial Fill, Greenville, MS 38701 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Greenville site logged 0 recordable injuries or illnesses among about 57 workers: 0.0 per 100 full-time workers, against a median of 0.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Farmers Grain Terminal - Greenville
Greenville · 2025
57 000.00.0
FGT - Greenville
Greenville · 2023
62 000.00.0

Included with any plan: 6 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.8 · Recording criteria for needlestick and sharps injuries

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(8)

(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.272 · Grain handling facilities

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

Other general warehousing and storage employers in Mississippi

Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.