OSHA SearchOSHA records by employer

Federico Santamaria: OSHA inspections and violations

Argyle, Texas · Roofing Contractors · NAICS 238160

1inspections
4citation items
$12,548current penalties
Mar 11, 2024last inspection

OSHA inspectors have visited Federico Santamaria in Texas one time.

It opened on Mar 11, 2024 as a planned inspection, in Argyle and is still open.

In all, OSHA issued 4 citation items: 2 serious and 2 repeat.

The proposed penalties came to $25,095; today they stand at $12,548, 50% less.

The rule cited most here is 1926.1052 (stairways in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Federico Santamaria averages $12,548 across 1 cited inspection.

Federico Santamaria: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Federico Santamaria again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347338758 OPENED MAR 11, 2024Open

Planned · Partial · Safety · 4 employees at the site · Open

5200 Edge Way, Argyle, TX 76226 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$5,323$2,662Mar 25, 2024Final
Citation 1, item 1b
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$0$0Mar 25, 2024Final
Citation 2, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Repeat$9,126$4,563Mar 25, 2024Final
Citation 2, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$10,646$5,323Mar 25, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1052(c)(12)

(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.