Inspection 347768236 OPENED SEP 19, 2024Closed
101 Peabody St. Lot 308, Savannah, GA 31407 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2024, OSHA inspectors have visited Fernando Hernandez Lopez in Georgia 2 times.
The most recent inspection opened on Sep 19, 2024 as a planned inspection, in Savannah.
In all, OSHA issued 2 citation items: 2 serious.
The proposed penalties came to $6,222; today they stand at $3,733, 40% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Fernando Hernandez Lopez averages $3,733 across 1 cited inspection.
Georgia · latest 90 days of OSHA records
145employers cited
27 of them in the same industry
Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Georgia
Checking a subcontractor, a client or your own company? Watch Fernando Hernandez Lopez and get notified the morning OSHA posts a new citation for it.
Watch this company101 Peabody St. Lot 308, Savannah, GA 31407 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
242 Brookline Dr., Savannah, GA 31407 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.306(b)(3)(i) · Air receivers |
Serious | $2,765 | $1,659 | Sep 13, 2024 | Final |
| Citation 1, item 2 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $3,457 | $2,074 | Sep 13, 2024 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.306(b)(3)(i)
(3) Gages and valves. (i) Every air receiver shall be equipped with an indicating pressure gage (so located as to be readily visible) and with one or more spring-loaded safety valves. The total relieving capacity of such safety valves shall be such as to prevent pressure in the receiver from exceeding the maximum allowable working pressure of the receiver by more than 10 percent.
29 CFR 1926.501(b)(13)
(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.
Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.