Ferrell Fire Company (Building): OSHA inspections and violations

Monroeville, New Jersey · Fire Protection · NAICS 922160

6inspections
11citation items
$7,700current penalties
Oct 17, 2017last inspection

OSHA has inspected Ferrell Fire Company (Building) 6 times in New Jersey since 2013.

The latest one began on Oct 17, 2017 to follow up on an earlier case, in Monroeville.

Those inspections ended with 11 citation items: 6 serious and 5 other-than-serious.

Penalties were first proposed at $7,700 and still stand at $7,700.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for public administration employers since 2015 is $0, and Ferrell Fire Company (Building) averages $7,700 (1 cited inspection).

Ferrell Fire Company (Building): OSHA citation items per year, 2013 to 2017
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

276employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Ferrell Fire Company (Building) and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342706397 OPENED OCT 17, 2017Closed

Follow-up · Partial · Safety · Local government · 23 employees at the site · Closed Oct 17, 2017

186 Elk Road, Monroeville, NJ 08343 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342596210 OPENED AUG 28, 2017Closed

Planned · Complete · Safety · Local government · 23 employees at the site · Closed Oct 17, 2017

186 Elk Road, Monroeville, NJ 08343 · Fire Protection · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$3,500$3,500Sep 11, 2017Final
Citation 1, item 2
29 CFR N.J.A.C. 12:100-10.16(A) (OPT
Serious$3,500$3,500Sep 11, 2017Final
Citation 2, item 1
29 CFR N.J.A.C. 12:100-7.8(A) (OPTION
Other-than-serious$700$700Sep 11, 2017Final

Inspection 317336337 OPENED SEP 12, 2013Closed

Follow-up · Partial · Safety · Local government · 25 employees at the site · Closed Sep 12, 2013

186 Elk Road, Monroeville, NJ 08343 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317336345 OPENED SEP 12, 2013Closed

Follow-up · Partial · Safety · Local government · 25 employees at the site · Closed Sep 12, 2013

186 Elk Road, Monroeville, NJ 08343 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316975119 OPENED AUG 1, 2013Closed

Planned · Complete · Safety · Local government · 25 employees at the site · Closed Sep 12, 2013

186 Elk Road, Monroeville, NJ 08343 · Fire Protection · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$0$0Aug 8, 2013Closed
Citation 1, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Aug 8, 2013Closed
Citation 1, item 3
29 CFR 1910.334(a)(3)(ii) · Using electrical equipment
Serious$0$0Aug 8, 2013Closed
Citation 2, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$0$0Aug 8, 2013Closed
Citation 2, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Aug 8, 2013Closed
Citation 2, item 3
29 CFR 70005 A
Other-than-serious$0$0Aug 8, 2013Closed
Citation 2, item 4
29 CFR 100016 B
Other-than-serious$0$0Aug 8, 2013Closed

Inspection 316975127 OPENED AUG 1, 2013Closed

Planned · Complete · Safety · Local government · 25 employees at the site · Closed Sep 12, 2013

186 Elk Road, Monroeville, NJ 08343 · Fire Protection · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 100007 B01
Serious$0$0Aug 8, 2013Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(g)(5)

(5) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment