OSHA SearchOSHA records by employer

Figozz Masonry, LLC: OSHA inspections and violations

Marietta, Georgia · Masonry Contractors · NAICS 238140

1inspections
4citation items
$4,433current penalties
Sep 3, 2019last inspection

OSHA has inspected Figozz Masonry, LLC once in Georgia.

The inspection began on Sep 3, 2019 as a planned inspection, in Marietta.

That inspection ended with 4 citation items: 3 serious and 1 other-than-serious.

Penalties were first proposed at $7,388 and now stand at $4,433, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Figozz Masonry, LLC averages $4,433 (1 cited inspection).

Figozz Masonry, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Figozz Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344277678 OPENED SEP 3, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 7, 2023

1420 Terrell Mill Road, Se, Marietta, GA 30067 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,273$1,478Oct 15, 2019Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,273$1,478Oct 15, 2019Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,842$1,477Oct 15, 2019Final
Citation 2, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Oct 15, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.