OSHA SearchOSHA records by employer

Fine Stucco Inc: OSHA inspections and violations

Cedar Knolls, New Jersey · Masonry Contractors · NAICS 238140

2inspections
4citation items
$11,141current penalties
Apr 21, 2025last inspection

Since 2024, OSHA inspectors have visited Fine Stucco Inc in New Jersey 2 times.

The most recent inspection opened on Apr 21, 2025, in Hasbrouck Heights and is still open.

In all, OSHA issued 4 citation items: 3 serious and 1 repeat.

The proposed penalties came to $22,177; today they stand at $11,141, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Fine Stucco Inc averages $5,570 across 2 cited inspections.

Fine Stucco Inc: OSHA citation items per year, 2024 to 2025
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

276employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Fine Stucco Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348193822 OPENED APR 21, 2025Open

Unprogrammed other · Partial · Safety · 4 employees at the site · Open

259 Lawrence Ave, Hasbrouck Heights, NJ 07604 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$4,965$2,500Aug 27, 2025Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Aug 27, 2025Final
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$9,930$5,000Aug 27, 2025Final

Inspection 347857757 OPENED NOV 1, 2024Open

Planned · Partial · Safety · 13 employees at the site · Open

235 Ridgedale Ave, Cedar Knolls, NJ 07927 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$7,282$3,641Mar 19, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

Other masonry contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.