OSHA SearchOSHA records by employer

Five Star Contractors, Inc.: OSHA inspections and violations

Wayne, Pennsylvania · Masonry Contractors · NAICS 238140

2inspections
12citation items
$16,800current penalties
Apr 3, 2017last inspection

OSHA has inspected Five Star Contractors, Inc. 2 times in Pennsylvania since 2011.

The latest one began on Apr 3, 2017 on a referral, in Zionsville.

Those inspections ended with 12 citation items: 12 serious.

Penalties were first proposed at $25,433 and now stand at $16,800, 34% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 8 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Five Star Contractors, Inc. averages $13,200 (1 cited inspection).

Five Star Contractors, Inc.: OSHA citation items per year, 2011 to 2017
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Five Star Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342220340 OPENED APR 3, 2017Closed

Referral · Partial · Safety · 16 employees at the site · Closed Mar 5, 2018

Lot 34 Granville Rd., Zionsville, PA 18092 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.28(a) · Personal protective equipment
Serious$2,897$2,000Apr 21, 2017Final
Citation 1, item 2
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$3,622$3,000Apr 21, 2017Final
Citation 1, item 5
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,622$3,200Apr 21, 2017Final
Citation 1, item 6a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$5,070$5,000Apr 21, 2017Final
Citation 1, item 6b
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$0$0Apr 21, 2017Final
Citation 1, item 6c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$3,622$0Apr 21, 2017Final
Citation 1, item 6d
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Apr 21, 2017Final

Inspection 314726407 OPENED SEP 29, 2011Closed

Referral · Partial · Safety · 9 employees at the site · Closed Dec 31, 2012

Brians Way, Wayne, PA 19087 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1a
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Serious$2,400$1,500Jan 23, 2012Closed
Citation 2, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Jan 23, 2012Closed
Citation 2, item 2a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,200$2,100Jan 23, 2012Closed
Citation 2, item 2b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Jan 23, 2012Closed
Citation 2, item 2c
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Jan 23, 2012Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.28(a)

(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.