OSHA SearchOSHA records by employer

Flat Glass Distributors: OSHA inspections and violations

Jacksonville, Florida · Flat Glass Manufacturing · NAICS 327211

2inspections
6citation items
$78,940current penalties
Oct 19, 2021last inspection

Flat Glass Distributors has 2 OSHA inspections on record in Florida, the first in 2020.

OSHA's last visit started on Oct 19, 2021 to follow up on an earlier case, in Jacksonville.

Across those inspections OSHA issued 6 citation items: 6 serious.

OSHA proposed $121,446 in penalties. After settlements and reviews the total is $78,940, down 35%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Flat Glass Distributors averages $78,940 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Flat Glass Distributors: OSHA citation items per year, 2020 to 2021
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

338employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Flat Glass Distributors and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345587547 OPENED OCT 19, 2021Closed

Follow-up · Partial · Safety · 73 employees at the site · Closed Oct 27, 2021

5355 Shawland Road, Jacksonville, FL 32203 · Flat Glass Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344615497 OPENED FEB 7, 2020Closed

Complaint · Partial · Safety · 64 employees at the site · Closed Jun 8, 2022

5355 Shawland Road, Jacksonville, FL 32254 · Flat Glass Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(3) · Walking-working surfaces
Serious$4,048$2,630May 14, 2020Final
Citation 1, item 2
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$6,747$4,385May 14, 2020Final
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$4,049$2,630May 14, 2020Final
Citation 1, item 4
29 CFR 1910.219(f)(1)(i) · Belts, pulleys and power-transmission parts
Serious$5,398$3,510May 14, 2020Final
Citation 1, item 5
29 CFR 1910.303(b)(6) · Electrical equipment, general requirements
Serious$6,747$4,385May 14, 2020Final
Citation 2, item 1
29 CFR 1910.179(l)(3)(i) · Overhead and gantry cranes
Serious$94,457$61,400May 14, 2020Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Nov 20, 2015, Jacksonville: Amputation · fractures and other injuries, n.e.c. · upper and lower limb(s)

An employee was inspecting a flat glass panel when the panel shifted and pinched the employee's left wrist and pinky finger between the glass panel and the machine's railing. The employee fell and amputated the left pinky finger and broke the left wrist and ankle.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.146(c)(1)

(c) General requirements. (1) The employer shall evaluate the workplace to determine if any spaces are permit- required confined spaces.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(l)(3)(i)

(3) Adjustments and repairs. (i) Any unsafe conditions disclosed by the inspection requirements of paragraph (j) of this section shall be corrected before operation of the crane is resumed. Adjustments and repairs shall be done only by designated personnel.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.303 · Electrical equipment, general requirements

Other flat glass manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.