OSHA has inspected Flawless Steel Welding LLC. 3 times in Colorado since 2015.
The latest one began on Mar 20, 2025 on a referral, in Denver; the case is still open.
Those inspections ended with 8 citation items: 8 other-than-serious.
Penalties were first proposed at $13,852 and now stand at $13,800, 0% lower after settlements or reviews.
Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Flawless Steel Welding LLC. averages $4,600 (3 cited inspections).
Flawless Steel Welding LLC. also files yearly injury logs with OSHA, summarized below.
It reported 3 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Colorado · latest 90 days of OSHA records
142employers cited
Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Flawless Steel Welding LLC. and get notified the morning OSHA posts a new citation for it.
Incident on Dec 29, 2016: Steel erector falls and fractures back and wrist
At 2:00 p.m. on December 29, 2016, Employee #1, employed by a steel welding company, was working as a subcontractor at a commercial building construction project. He was laying decking on a new level during structural steel erection activities. Employee #1 feel through an opening to the ground, a fall height of approximately 19 feet. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for a concussion, fractured back and wrist. The subsequent investigation established a lack of fall protection devices.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2019, the Denver site logged 0 recordable injuries or illnesses among about 27 workers: 0.0 per 100 full-time workers, against a median of 3.6 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Flawless Steel Welding
Denver · 2019
27
0
0
0.0
3.6
Severe injury reports
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.
Mar 17, 2025, Denver: Hospitalization · fractures · leg(s) unspecified
An employee was moving a 20-foot-long steel beam using an overhead crane. After lowering the beam onto dunnage wood, the employee unhooked it and began to move the crane. The crane's lifting attachment, which had not been fully removed, lifted the beam and caused it to roll toward a nearby pile of steel. The beam pushed the employee into the pile of steel and he suffered a broken leg.
Feb 26, 2021, Denver: Hospitalization · fractures · hip(s)
An employee was walking into the workplace and slipped and fell on ice, resulting in a broken hip.
Dec 29, 2016, Johnstown: Hospitalization · fractures · wrist(s)
An employee was installing decking and transferring from a static fall protection line. The employee disconnected from one anchor and was trying to reattach to another when the employee fell 15 feet to the ground, suffering a broken wrist and requiring hospitalization.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.
29 CFR 1910.157(e)(1)
(e) Inspection, maintenance and testing. (1) The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace.
(i) Bandsaws and band resaws. (1) All portions of the saw blade shall be enclosed or guarded, except for the working portion of the blade between the bottom of the guide rolls and the table. Bandsaw wheels shall be fully encased. The outside periphery of the enclosure shall be solid. The front and back of the band wheels shall be either enclosed by solid material or by wire mesh or perforated metal. Such mesh or perforated metal shall be not less than 0.037 inch (U.S. Gage No. 20), and the openings shall be not greater than three-eighths inch. Solid material used for this purpose shall be of an equivalent strength and firmness. The guard for the portion of the blade between the sliding guide and the upper-saw-wheel guard shall protect the saw blade at the front and outer side. This portion of the guard shall be self-adjusting to raise and lower with the guide. The upper-wheel guard shall
Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.