OSHA SearchOSHA records by employer

Flight Mold & Engineering Inc: OSHA inspections and violations

Saint Clair, Michigan · Industrial Mold Manufacturing · NAICS 333511

3inspections
45citation items
$5,625current penalties
Jan 2, 2018last inspection

Since 2006, OSHA inspectors have visited Flight Mold & Engineering Inc in Michigan 3 times.

The most recent inspection opened on Jan 2, 2018 as a planned inspection, in Saint Clair.

In all, OSHA issued 45 citation items: 12 serious, 3 repeat and 30 other-than-serious.

The proposed penalties came to $11,250; today they stand at $5,625, 50% less.

The rule cited most here is 1910.147 (lockout/tagout), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Flight Mold & Engineering Inc averages $1,350 across 1 cited inspection.

Flight Mold & Engineering Inc: OSHA citation items per year, 2006 to 2018
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

656employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Flight Mold & Engineering Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342857018 OPENED JAN 2, 2018Closed

Planned · Complete · Safety · 30 employees at the site · Closed Feb 21, 2018

1940 Fred W Moore Hwy, Saint Clair, MI 48079 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10034(10)
Serious$1,500$750Jan 18, 2018Final
Citation 1, item 2
29 CFR 408.16242
Serious$1,200$600Jan 18, 2018Final
Citation 2, item 1
29 CFR 408.10125
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 2
29 CFR 408.10454(3)
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 3
29 CFR 408.11854(1)
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 4
29 CFR 408.12373
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 5
29 CFR 408.13308(3)
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 6a
29 CFR 408.14912(1)
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 6b
29 CFR 408.14923(1)
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 6c
29 CFR 408.14921
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 7a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 7b
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 7c
29 CFR 1910.147(c)(7)(i)(b) · Lockout/tagout
Other-than-serious$0$0Jan 18, 2018Final
Citation 2, item 8
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 18, 2018Final

Inspection 312008774 OPENED JUL 8, 2009Closed

Planned · Complete · Safety · 14 employees at the site · Closed Sep 16, 2009

1940 Fred Moore Hwy, Saint Clair, MI 48079 · Industrial Mold Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Repeat$600$300Aug 12, 2009Closed
Citation 2, item 1 Other-than-serious$0$0Aug 12, 2009Closed
Citation 2, item 2 Other-than-serious$0$0Aug 12, 2009Closed
Citation 2, item 3 Other-than-serious$0$0Aug 12, 2009Closed
Citation 2, item 4
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Aug 12, 2009Closed
Citation 3, item 1 Repeat$100$50Aug 12, 2009Closed
Citation 3, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Repeat$100$50Aug 12, 2009Closed

Inspection 308801059 OPENED APR 21, 2006Closed

Planned · Complete · Safety · 28 employees at the site · Closed Aug 30, 2006

1940 Fred Moore Hwy, Saint Clair, MI 48079 · Industrial Mold Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$750$375Jul 11, 2006Closed
Citation 1, item 2 Serious$750$375Jul 11, 2006Closed
Citation 1, item 3 Serious$750$375Jul 11, 2006Closed
Citation 1, item 4 Serious$750$375Jul 11, 2006Closed
Citation 1, item 5
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$750$375Jul 11, 2006Closed
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,000$500Jul 11, 2006Closed
Citation 1, item 7
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,000$500Jul 11, 2006Closed
Citation 1, item 8a
29 CFR 1910.106(e)(2)(iib)(1) · Flammable liquids
Serious$750$375Jul 11, 2006Closed
Citation 1, item 8b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Jul 11, 2006Closed
Citation 1, item 9
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$750$375Jul 11, 2006Closed
Citation 2, item 1 Other-than-serious$500$250Jul 11, 2006Closed
Citation 2, item 2 Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 3 Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 4 Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 5 Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 6 Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 7 Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 8 Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 9 Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 10 Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 11
29 CFR 1910.303(g)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 12
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 13 Other-than-serious$0$0Jul 11, 2006Closed
Citation 2, item 14 Other-than-serious$0$0Jul 11, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(iib)(1)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 4081.1222

29 CFR 4081.125

29 CFR 4081.15

29 CFR 4081.1854

29 CFR 4081.1871

29 CFR 4081.2041

29 CFR 4081.2042

29 CFR 4081.213

29 CFR 4081.2154

29 CFR 4081.2635

29 CFR 4081.2648

29 CFR 4081.3308

29 CFR 4081.3370

29 CFR 4081.4912

29 CFR 4081.4932

29 CFR 4081.632

29 CFR 4081.645

29 CFR 4081.727

29 CFR 4082.2132

Other industrial mold manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.