OSHA SearchOSHA records by employer

Floatation Docking, Inc.: OSHA inspections and violations

Cedarville, Michigan · Marinas · NAICS 713930

1inspections
4citation items
$4,865current penalties
Jul 20, 2016last inspection

OSHA inspectors have visited Floatation Docking, Inc. in Michigan one time.

It opened on Jul 20, 2016 as a planned inspection, in Cedarville.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $6,950; today they stand at $4,865, 30% less.

Among arts and recreation employers, the typical cited inspection since 2015 ends with a $1,400 penalty. Floatation Docking, Inc. averages $4,865 across 1 cited inspection.

Floatation Docking, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Floatation Docking, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341637296 OPENED JUL 20, 2016Closed

Planned · Complete · Safety · 10 employees at the site · Closed Oct 6, 2016

100 E Hodeck St, Cedarville, MI 49719 · Marinas · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(m)(1) · Overhead and gantry cranes
Serious$1,604$1,123Aug 8, 2016Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$1,604$1,123Aug 8, 2016Final
Citation 1, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$1,604$1,123Aug 8, 2016Final
Citation 1, item 4
29 CFR 1915.502(a) · Fire safety plan
Serious$2,138$1,497Aug 8, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(m)(1)

(m) Rope inspection—(1) Running ropes. A thorough inspection of all ropes shall be made at least once a month and a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier for the ropes which were inspected shall be kept on file where readily available to appointed personnel. Any deterioration, resulting in appreciable loss of original strength, shall be carefully observed and determination made as to whether further use of the rope would constitute a safety hazard. Some of the conditions that could result in an appreciable loss of strength are the following:

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.242(b)

(b) Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1915.502 · Fire safety plan

Other marinas employers in Michigan

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.