OSHA SearchOSHA records by employer

Flores Construction & Stucco, LLC: OSHA inspections and violations

Pecos, Texas · Industrial Building Construction · NAICS 236210

2inspections
3citation items
$6,819current penalties
Feb 12, 2020last inspection

Flores Construction & Stucco, LLC has 2 OSHA inspections on record in Texas, the first in 2019.

OSHA's last visit started on Feb 12, 2020 to follow up on an earlier case, in Pecos.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $6,819 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Flores Construction & Stucco, LLC averages $6,819 over 1 cited inspection in that time.

Flores Construction & Stucco, LLC: OSHA citation items per year, 2019 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Flores Construction & Stucco, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344634563 OPENED FEB 12, 2020Closed

Follow-up · No inspection · Safety · 5 employees at the site · Closed Feb 19, 2020

131 S. Interstate Frontage Rd., Pecos, TX 79772 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344407382 OPENED OCT 22, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jun 1, 2023

131 S. Frontage Road, Pecos, TX 79772 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,273$2,273Dec 11, 2019Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,273$2,273Dec 11, 2019Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,273$2,273Dec 11, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.