Inspection 347358699 OPENED MAR 20, 2024Closed
1228 Nw Us 221, Greenville, FL 32331 · Hardwood Veneer and Plywood Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Greenville, Florida · Hardwood Veneer and Plywood Manufacturing · NAICS 321211
Florida Plywoods, Inc. has 6 OSHA inspections on record in Florida, the first in 1997.
OSHA's last visit started on Mar 20, 2024 as a planned inspection, in Greenville.
Across those inspections OSHA issued 4 citation items: 1 serious and 3 other-than-serious.
OSHA proposed $7,252 in penalties. After settlements and reviews the total is $4,351, down 40%.
Most often, OSHA cited 1910.22, walking-working surfaces (2 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Florida Plywoods, Inc. averages $1,450 over 3 cited inspections in that time.
Florida Plywoods, Inc. also files yearly injury logs with OSHA, summarized below.
Florida · latest 90 days of OSHA records
319employers cited
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch Florida Plywoods, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company1228 Nw Us 221, Greenville, FL 32331 · Hardwood Veneer and Plywood Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1228 Nw Us 221, Greenville, FL 32331 · Hardwood Veneer and Plywood Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(2) · Walking-working surfaces |
Other-than-serious | $0 | $0 | May 23, 2022 | Final |
1228 Nw Us 221, Greenville, FL 32331 · Hardwood Veneer and Plywood Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(c)(1) · Noise |
Serious | $7,252 | $4,351 | Feb 11, 2022 | Final |
| Citation 2, item 1 29 CFR 1910.305(j)(1)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Feb 11, 2022 | Final |
1228 Nw Us 221, Greenville, FL 32331 · Hardwood Veneer and Plywood Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(1) · Walking-working surfaces |
Other-than-serious | $0 | $0 | Jun 8, 2018 | Final |
1228 Nw Us 221, Greenville, FL 32331 · Hardwood Veneer and Plywood Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
U.s. Hwy 221 North, Greenville, FL 32331 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Greenville site logged 8 recordable injuries or illnesses among about 40 workers: 18.9 per 100 full-time workers, against a median of 3.9 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Florida Plywoods Inc Greenville · 2025 | 40 | 8 | 0 | 18.9 | 3.9 |
| Florida Plywoods, Inc. Greenville · 2023 | 41 | 1 | 0 | 2.2 | 3.9 |
Included with any plan: 6 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.22(a)(1)
(1) All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.
29 CFR 1910.22(a)(2)
(2) The floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. When wet processes are used, drainage must be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats must be provided.
29 CFR 1910.305(j)(1)(i)
(j) Equipment for general use—(1) Lighting fixtures, lampholders, lamps, and receptacles. (i) Fixtures, lampholders, lamps, rosettes, and receptacles may have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 2.44 m (8.0 ft) above the floor may have exposed terminals.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.