Florida Solar & Air, Inc.: OSHA inspections and violations

Coral Gables, Florida · Glass and Glazing Contractors · NAICS 238150

1inspections
5citation items
$17,100current penalties
Feb 7, 2024last inspection

Florida Solar & Air, Inc. has one OSHA inspection on record in Florida.

OSHA opened it on Feb 7, 2024 after a complaint, in Coral Gables.

From that inspection OSHA issued 5 citation items: 5 other-than-serious.

OSHA proposed $29,037 in penalties. After settlements and reviews the total is $17,100, down 41%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Florida Solar & Air, Inc. averages $17,100 over 1 cited inspection in that time.

Florida Solar & Air, Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Florida Solar & Air, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347264079 OPENED FEB 7, 2024Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Dec 16, 2025

7424 Vistalmar Street, Coral Gables, FL 33143 · Glass and Glazing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$4,839$2,420May 17, 2024Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$6,453$4,517May 17, 2024Final
Citation 1, item 3
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Other-than-serious$6,453$3,226May 17, 2024Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Other-than-serious$6,453$4,517May 17, 2024Final
Citation 1, item 5
29 CFR 1926.452(w)(9) · Rules for each type of scaffold
Other-than-serious$4,839$2,420May 17, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.452 · Rules for each type of scaffold