OSHA SearchOSHA records by employer

Floyd County Sanitation Maintenance Shop: OSHA inspections and violations

Floyd, Virginia · Other General Government Support · NAICS 921190

1inspections
3citation items
$0current penalties
Sep 25, 2024last inspection

OSHA has inspected Floyd County Sanitation Maintenance Shop once in Virginia.

The inspection began on Sep 25, 2024 as a planned inspection, in Floyd.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

None of the citations carried a penalty.

How that compares: the median penalty per cited inspection for public administration employers since 2015 is $0, and Floyd County Sanitation Maintenance Shop averages $0 (1 cited inspection).

Floyd County Sanitation Maintenance Shop: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Floyd County Sanitation Maintenance Shop and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347777252 OPENED SEP 25, 2024Closed

Planned · Complete · Safety · Local government · 1 employee at the site · Closed Nov 27, 2024

139 Transfer Station Rd, Floyd, VA 24091 · Other General Government Support · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$0$0Nov 12, 2024Final
Citation 1, item 2
29 CFR 1910.303(b)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Nov 12, 2024Final
Citation 2, item 1
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Nov 12, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(1)(ii)

(ii) Mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided;

Other other general government support employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.