OSHA SearchOSHA records by employer

Fluid-Aire Dynamics Inc: OSHA inspections and violations

Wixom, Michigan · Air and Gas Compressor Manufacturing · NAICS 333912

1inspections
1citation items
$3,500current penalties
May 24, 2022last inspection

OSHA has inspected Fluid-Aire Dynamics Inc once in Michigan.

The inspection began on May 24, 2022 on a referral, in Wixom; the case is still open.

That inspection ended with 1 citation item: 1 serious.

Penalties were first proposed at $3,500 and still stand at $3,500.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Fluid-Aire Dynamics Inc averages $3,500 (1 cited inspection).

Fluid-Aire Dynamics Inc: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

647employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Fluid-Aire Dynamics Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345977516 OPENED MAY 24, 2022Open

Referral · Partial · Safety · 2 employees at the site · Open

50469 Pontiac Trail, Wixom, MI 48393 · Air and Gas Compressor Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$3,500$3,500Jul 18, 2022Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

Other air and gas compressor manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.