Inspection 348651332 OPENED DEC 18, 2025Closed
3100 Se Maricamp Rd, Ocala, FL 34471 · Rubber and Plastics Hoses and Belting Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Fluid Routing Solutions LLC 4 times in Florida since 2012.
The latest one began on Dec 18, 2025 after a complaint, in Ocala.
Those inspections ended with 3 citation items: 1 serious and 2 other-than-serious.
Penalties were first proposed at $28,899 and now stand at $22,447, 22% lower after settlements or reviews.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Fluid Routing Solutions LLC averages $11,223 (2 cited inspections).
Fluid Routing Solutions LLC also files yearly injury logs with OSHA, summarized below.
Florida · latest 90 days of OSHA records
326employers cited
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch Fluid Routing Solutions LLC and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Fluid Routing Solutions LLC at 3 sites in 3 states. Together they've had 21 inspections and $72,097 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans3100 Se Maricamp Rd, Ocala, FL 34471 · Rubber and Plastics Hoses and Belting Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3100 Se Maricamp Rd, Ocala, FL 34471 · Rubber and Plastics Hoses and Belting Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Other-than-serious | $12,768 | $12,768 | Sep 11, 2025 | Final |
3100 Se Maricamp Rd, Ocala, FL 34471 · Rubber and Plastics Hoses and Belting Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $11,292 | $6,775 | Apr 18, 2024 | Final |
| Citation 1, item 2 29 CFR 1910.37(b)(4) · Exit routes |
Other-than-serious | $4,839 | $2,903 | Apr 18, 2024 | Final |
3100 Se Maricamp Rd, Ocala, FL 34471 · Rubber and Plastics Hoses and Belting Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Ocala site logged 5 recordable injuries or illnesses among about 98 workers: 4.8 per 100 full-time workers, against a median of 2.9 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Fluid Routing Solutions Ocala Ocala · 2025 | 98 | 5 | 0 | 4.8 | 2.9 |
| Fluid Routing Solutions - Ocala Ocala · 2021 | 123 | 12 | 10 | 11.6 | 2.9 |
| Fluid Routing Solutions Ocala · 2020 | 98 | 3 | 3 | 3.5 | 2.9 |
Included with any plan: 2 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.132(a)
(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.
29 CFR 1910.212(a)(1)
(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.
29 CFR 1910.37(b)(4)
(4) If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge. Additionally, the line-of-sight to an exit sign must clearly be visible at all times.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.