Fluor Daniel Service Corporation: OSHA inspections and violations

Freeport, Texas · Industrial Building Construction · NAICS 236210

1inspections
2citation items
$14,000current penalties
Jul 7, 2015last inspection

OSHA inspectors have visited Fluor Daniel Service Corporation in Texas one time.

It opened on Jul 7, 2015 after a fatality or catastrophe, in Freeport.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $14,000 in total, stand where OSHA first set them.

The rule cited most here is 1910.134 (respiratory protection), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Fluor Daniel Service Corporation averages $14,000 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Fluor Daniel Service Corporation: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Fluor Daniel Service Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340915230 OPENED JUL 7, 2015Closed

Fatality or catastrophe · Complete · Safety · 200 employees at the site · Closed Dec 14, 2016

2301 North Brazosport Blvd., Freeport, TX 77541 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Incident on Jul 6, 2015 (fatal): Employee is killed when overcome by unknown substance

At 11:45 p.m. on July 6, 2015, an employee and two coworkers were retrieving a balloon dam from a 48 inch line that failed. The employee entered the line and got to a double 90 to the lower section that was approximately 20 feet away. The employee was lowered down to the damaged balloon and was subsequently overcome by an unknown substance that caused him to become unconscious while climbing back to the upper level. The employee was killed from asphyxiation. from asphyxiation.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.134(d)(2)(i) · Respiratory protection
Serious$7,000$7,000Jan 5, 2016Final
Citation 1, item 3
29 CFR 1910.134(g)(3)(vi)(b) · Respiratory protection
Serious$7,000$7,000Jan 5, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(d)(2)(i)

(2) Respirators for IDLH atmospheres. (i) The employer shall provide the following respirators for employee use in IDLH atmospheres:

29 CFR 1910.134(g)(3)(vi)(b)

(B) Appropriate retrieval equipment for removing the employee(s) who enter(s) these hazardous atmospheres where retrieval equipment would contribute to the rescue of the employee(s) and would not increase the overall risk resulting from entry; or

Other industrial building construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.