Fluor Enterprises, Inc.: OSHA inspections and violations
Augusta, Georgia · Industrial Building Construction · NAICS 236210
8inspections
7citation items
$670current penalties
Sep 28, 2016last inspection
Since 1990, OSHA inspectors have visited Fluor Enterprises, Inc. in Georgia 8 times.
The most recent inspection opened on Sep 28, 2016 after a complaint, in Waynesboro.
In all, OSHA issued 7 citation items: 2 serious and 5 other-than-serious.
The proposed penalties came to $910; today they stand at $670, 26% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Fluor Enterprises, Inc. averages $0 across 1 cited inspection.
1 inspection on this page followed a fatal incident.
It reported 3 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Georgia · latest 90 days of OSHA records
146employers cited
Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.
OSHA records show Fluor Enterprises, Inc. at 6 sites in 2 states. Together they've had 10 inspections and $2,620 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 6 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Incident on Aug 17, 1990 (fatal): Electric shock - direct contact with energized parts
TWO EMPLOYEES WERE REMOVING A CONDUIT FROM A BEAM THAT WAS TO BE TAKEN OUT. TWO OVERHEAD LIGHTING FIXTURES WERE SUPPLIED BY THIS CONDUIT, AND THE EMPLOYEES WERE INSTALLING A NON-METALLIC SHEATHED CABLE BETWEEN TWO JUNCTION BOXES TO REPLACE IT. ONE OF THE TWO EMPLOYEES DECIDED TO WIRE ONE OF THE JUNCTION BOXES WHILE IT REMAINED ENERGIZED AT 480/277 VOLTS (THREE PHASE, FOUR WIRE). THE EMPLOYEE SUCCE SSFULLY CONNECTED THE BLACK CONDUCTOR, INSTALLING A WIRE NUT AND TAPING THE CONN ECTION. HE HAD CONTACTED AN ENERGIZED PART AND HAD RECEIVED AN ELECTRIC SHOCK. H OWEVER, HE CONTINUED TO WORK WITH THE CIRCUIT ENERGIZED. HE THEN APPARENTLY BEGA N TO STRIP THE INSULATION FROM THE RED CONDUCTOR. HE RECEIVED A SECOND ELECTRIC SHOCK AND WAS ELECTROCUTED. HIS EMPLOYER HAD A LOCKOUT AND TAGGING PROGRAM AND A N ELECTRICAL HOT WORK PERMIT SYSTEM IN PLACE. THE PROGRAMS WERE EFFECTIVELY COMM UNICATED TO EMPLOYEES AND WERE UNIFORMLY ENFORCED.
No citations from this inspection.
Inspection 110103678 OPENED JUN 25, 1990Closed
Planned · Complete · Safety · 2,600 employees at the site · Closed Jan 14, 1991
An employee was holding the rigging line while he was signaling the operator to lift the load. As the load was lifted up, it shifted and his left hand little finger was caught between the rigging strap and the lifting box and was amputated.
Oct 31, 2016, Waynesboro: Amputation · amputations · fingertip(s)
When handling a 4 foot waler and loosening bolts, an employee's finger was caught between metal bolts and the waler, amputating the left middle distal fingertip.
Two employees were removing form panels from an upper elevation while working from the basket of a lift. One of the employees had his right hand on the basket's handrail, which came in contact with the building's steel beam. The employee suffered a partial amputation of the right ring fingertip.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1020 · Access to employee exposure and medical records
29 CFR 1910.1020(g)(1)
(g) Employee information. (1) Upon an employee's first entering into employment, and at least annually thereafter, each employer shall inform current employees covered by this section of the following:
(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.