OSHA SearchOSHA records by employer

For Him Logistics LLC: OSHA inspections and violations

North Brunswick, New Jersey · Masonry Contractors · NAICS 238140

1inspections
3citation items
$3,992current penalties
Jan 31, 2018last inspection

OSHA has inspected For Him Logistics LLC once in New Jersey.

The inspection began on Jan 31, 2018 on a referral, in North Brunswick.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $6,652 and now stand at $3,992, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and For Him Logistics LLC averages $3,992 (1 cited inspection).

For Him Logistics LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch For Him Logistics LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342926656 OPENED JAN 31, 2018Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jan 11, 2023

546 Georges Rd, North Brunswick, NJ 08902 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,772$1,331Feb 15, 2018Final
Citation 2, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,217$1,331Feb 15, 2018Final
Citation 2, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,663$1,330Feb 15, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

Other masonry contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.