Inspection 343885992 OPENED MAR 28, 2019Closed
380 Meyer Road, Bensenville, IL 60106 · Spring Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Bensenville, Illinois · Spring Manufacturing · NAICS 332613
Since 1996, OSHA inspectors have visited Form-All Spring & Stamping Company, Inc. in Illinois 5 times.
The most recent inspection opened on Mar 28, 2019 to monitor an earlier case, in Bensenville.
In all, OSHA issued 13 citation items: 11 serious and 2 other-than-serious.
The proposed penalties came to $12,148; today they stand at $6,434, 47% less.
The rule cited most here is 1910.106 (flammable liquids), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Form-All Spring & Stamping Company, Inc. averages $5,174 across 1 cited inspection.
Illinois · latest 90 days of OSHA records
416employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Illinois
Checking a subcontractor, a client or your own company? Watch Form-All Spring & Stamping Company, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company380 Meyer Road, Bensenville, IL 60106 · Spring Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
380 Meyer Road, Bensenville, IL 60106 · Spring Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
380 Meyer Road, Bensenville, IL 60106 · Spring Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $3,696 | $1,848 | Jun 6, 2018 | Final |
| Citation 1, item 2a 29 CFR 1910.219(b)(2) · Belts, pulleys and power-transmission parts |
Serious | $3,696 | $1,848 | Jun 6, 2018 | Final |
| Citation 1, item 2b 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Jun 6, 2018 | Final |
| Citation 1, item 2c 29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Jun 6, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.243(a)(3) · Guarding of portable powered tools |
Other-than-serious | $2,956 | $1,478 | Jun 6, 2018 | Final |
380 Meyer Rd., Bensenville, IL 60106 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
380 Meyer Rd., Bensenville, IL 60106 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.106(d)(4)(iii) · Flammable liquids |
Serious | $600 | $420 | Nov 29, 1996 | Closed |
| Citation 1, item 1b 29 CFR 1910.106(d)(4)(i) · Flammable liquids |
Serious | $0 | $0 | Nov 29, 1996 | Closed |
| Citation 1, item 1c 29 CFR 1910.106(d)(4)(iv) · Flammable liquids |
Serious | $0 | $0 | Nov 29, 1996 | Closed |
| Citation 1, item 1d 29 CFR 1910.106(d)(4)(iv) · Flammable liquids |
Serious | $0 | $0 | Nov 29, 1996 | Closed |
| Citation 1, item 1e 29 CFR 1910.106(d)(4)(iv) · Flammable liquids |
Serious | $0 | $0 | Nov 29, 1996 | Closed |
| Citation 1, item 2 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $600 | $420 | Nov 29, 1996 | Closed |
| Citation 1, item 3 29 CFR 1910.242(b) · Hand and power tools |
Serious | $600 | $420 | Nov 29, 1996 | Closed |
| Citation 2, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Nov 29, 1996 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(4)(i)
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.106(d)(4)(iii)
(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.
29 CFR 1910.106(d)(4)(iv)
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.