Inspection 349083063 OPENED JUL 30, 2026Open
1700 W. 166th Ave., Broomfield, Co 80023, Broomfield, CO 80023 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Since 2019, OSHA inspectors have visited Fortress Framing, Inc. in Colorado 13 times.
The most recent inspection opened on Jul 30, 2026 after a complaint, in Broomfield and is still open.
In all, OSHA issued 12 citation items: 3 serious, 3 repeat and 6 other-than-serious.
The proposed penalties came to $79,585; today they stand at $46,166, 42% less.
The rule cited most here is 1926.501 (fall protection in construction), 5 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Fortress Framing, Inc. averages $7,694 across 6 cited inspections.
Colorado · latest 90 days of OSHA records
138employers cited
24 of them in the same industry
Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Colorado
Checking a subcontractor, a client or your own company? Watch Fortress Framing, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company1700 W. 166th Ave., Broomfield, Co 80023, Broomfield, CO 80023 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
14562 Hudson Way, Thornton, CO 80602 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2a 29 CFR 1926.454(b) · Scaffold training |
Other-than-serious | $3,405 | $3,405 | Sep 8, 2026 | Final |
| Citation 1, item 2b 29 CFR 1926.454(a) · Scaffold training |
Other-than-serious | $0 | $0 | Sep 8, 2026 | Final |
| Citation 1, item 2c 29 CFR 1926.451(f)(7) · Scaffolds, general requirements |
Other-than-serious | $0 | $0 | Sep 8, 2026 | Final |
| Citation 1, item 4 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $3,405 | $3,405 | Sep 8, 2026 | Final |
Corner Of Punter St And Cowbell Dr, Erie, CO 80516 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Other-than-serious | $4,256 | $4,256 | Aug 21, 2026 | Final |
4569 Weitbrec Lane, Castle Rock, CO 80104 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
16588 Black Rose Circle, Parker, CO 80134 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2165 Grayside Cir, Castle Rock, CO 80104 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
13284 Platinum Ct., Parker, CO 80134 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $35,488 | $18,500 | Aug 19, 2024 | Final |
28406 E 6th Place, Aurora, CO 80018 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6107 E 141st Lane, Thornton, CO 80602 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2a 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $4,144 | $2,000 | Jan 11, 2023 | Final |
| Citation 1, item 2b 29 CFR 1926.1053(b)(6) · Ladders in construction |
Serious | $0 | $0 | Jan 11, 2023 | Final |
| Citation 2, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $11,602 | $5,000 | Jan 11, 2023 | Final |
10374 Detroit St, Thornton, CO 80229 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $11,602 | $6,000 | Jan 11, 2023 | Final |
13371 Blue Amber Ct, Parker, CO 80134 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4347 S Netherland Ct, Aurora, CO 80015 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
11591 26th Ave., Aurora, CO 80010 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Other-than-serious | $3,978 | $3,100 | Jun 20, 2019 | Final |
| Citation 1, item 2 29 CFR 1926.1053(b)(13) · Ladders in construction |
Other-than-serious | $1,705 | $500 | Jun 20, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.1053(b)(13)
(13) The top or top step of a stepladder shall not be used as a step.
29 CFR 1926.1053(b)(6)
(6) Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.
Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.