OSHA SearchOSHA records by employer

Foschini General Masonry: OSHA inspections and violations

Philadelphia, Pennsylvania · Masonry Contractors · NAICS 238140

2inspections
4citation items
$2,812current penalties
Jun 16, 2025last inspection

Since 1997, OSHA inspectors have visited Foschini General Masonry in Pennsylvania 2 times.

The most recent inspection opened on Jun 16, 2025 on a referral, in Philadelphia and is still open.

In all, OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

The proposed penalties came to $5,574; today they stand at $2,812, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Foschini General Masonry averages $2,412 across 1 cited inspection.

Foschini General Masonry: OSHA citation items per year, 1997 to 2025
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

300employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Foschini General Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348313180 OPENED JUN 16, 2025Open

Referral · Partial · Safety · 4 employees at the site · Open

734 S 9th Street, Philadelphia, PA 19147 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$2,412$1,206Dec 5, 2025Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Other-than-serious$2,412$1,206Dec 5, 2025Final

Inspection 102940004 OPENED MAY 16, 1997Closed

Referral · Partial · Safety · 3 employees at the site · Closed Jan 8, 2003

1200 Reed Street, Philadelphia, PA 19147 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$750$400Jul 3, 1997Closed
Citation 1, item 1b
29 CFR 1926.451(g)(3) · Scaffolds, general requirements
Serious$0$0Jul 3, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

Other masonry contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.