OSHA SearchOSHA records by employer

Foundry Construction LLC: OSHA inspections and violations

Washington, District of Columbia · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

1inspections
3citation items
$9,930current penalties
Jan 30, 2025last inspection

OSHA inspectors have visited Foundry Construction LLC in District of Columbia one time.

It opened on Jan 30, 2025 as a planned inspection, in Washington.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $9,930 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Foundry Construction LLC averages $9,930 across 1 cited inspection.

Foundry Construction LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Foundry Construction LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348015942 OPENED JAN 30, 2025Closed

Planned · Complete · Safety · 4 employees at the site · Closed Aug 7, 2025

3427 Wisconsin Ave Nw, Washington, DC 20016 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(k)(1) · Excavations
Serious$4,965$4,965Jul 11, 2025Final
Citation 1, item 1b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Jul 11, 2025Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$4,965$4,965Jul 11, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(b)

(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.

Other new multifamily housing construction (except for-sale builders) employers in District of Columbia

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.