OSHA SearchOSHA records by employer

Fountainbleau Construction, LLC: OSHA inspections and violations

New Orleans, Louisiana · Commercial and Institutional Building Construction · NAICS 236220

1inspections
4citation items
$7,700current penalties
Jan 23, 2015last inspection

Fountainbleau Construction, LLC has one OSHA inspection on record in Louisiana.

OSHA opened it on Jan 23, 2015 as a planned inspection, in New Orleans.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $7,700 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.405, job-site wiring (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Fountainbleau Construction, LLC averages $7,700 over 1 cited inspection in that time.

Fountainbleau Construction, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Fountainbleau Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340201573 OPENED JAN 23, 2015Closed

Planned · Partial · Safety · 21 employees at the site · Closed Jul 7, 2015

129 Roosevelt Way Or 129 University Place, New Orleans, LA 70112 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$2,000$2,000Apr 14, 2015Final
Citation 1, item 2
29 CFR 1926.405(d) · Job-site wiring
Serious$2,000$2,000Apr 14, 2015Final
Citation 1, item 3
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$2,000$2,000Apr 14, 2015Final
Citation 1, item 4
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$1,700$1,700Apr 14, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.405(d)

(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(i)

(5)(i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.501 · Fall protection in construction

Other commercial and institutional building construction employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.