OSHA SearchOSHA records by employer

Fowler Heating & Cooling, Inc: OSHA inspections and violations

Marion, Illinois · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
5citation items
$14,064current penalties
Feb 15, 2023last inspection

OSHA has inspected Fowler Heating & Cooling, Inc once in Illinois.

The inspection began on Feb 15, 2023 after a complaint, in Marion.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $23,439 and now stand at $14,064, 40% lower after settlements or reviews.

Gas welding and cutting comes up most often in these citations: 2 items under 1910.253.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Fowler Heating & Cooling, Inc averages $14,064 (1 cited inspection).

Fowler Heating & Cooling, Inc: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

416employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Fowler Heating & Cooling, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346514433 OPENED FEB 15, 2023Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Jul 24, 2023

423 South Court Street, Marion, IL 62959 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$7,813$4,688Jun 16, 2023Final
Citation 1, item 2
29 CFR 1910.29(b)(1) · Fall protection systems in general industry
Serious$7,813$4,688Jun 16, 2023Final
Citation 1, item 3a
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$7,813$4,688Jun 16, 2023Final
Citation 1, item 3b
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$0$0Jun 16, 2023Final
Citation 1, item 3c
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$0$0Jun 16, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(2)(ii)

(ii) Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.

29 CFR 1910.253(b)(2)(iv)

(iv) Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.29 · Fall protection systems in general industry

Other plumbing, heating, and air-conditioning contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.