OSHA SearchOSHA records by employer

FP Masonry LLC: OSHA inspections and violations

Fairburn, Georgia · Masonry Contractors · NAICS 238140

1inspections
8citation items
$23,834current penalties
Sep 18, 2025last inspection

OSHA has inspected FP Masonry LLC once in Georgia.

The inspection began on Sep 18, 2025 as a planned inspection, in Fairburn; the case is still open.

That inspection ended with 8 citation items: 8 serious.

Penalties were first proposed at $23,834 and still stand at $23,834.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and FP Masonry LLC averages $23,834 (1 cited inspection).

FP Masonry LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

142employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch FP Masonry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348513920 OPENED SEP 18, 2025Open

Planned · Partial · Safety · 3 employees at the site · Open

5373 Tolar Road, Fairburn, GA 30213 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$2,838$2,838Feb 9, 2026Contested
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,972$3,972Feb 9, 2026Contested
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$3,405$3,405Feb 9, 2026Contested
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,405$3,405Feb 9, 2026Contested
Citation 1, item 5
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$3,972$3,972Feb 9, 2026Contested
Citation 1, item 6a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,972$3,972Feb 9, 2026Contested
Citation 1, item 6b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Feb 9, 2026Contested
Citation 1, item 7
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,270$2,270Feb 9, 2026Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(i)

(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other masonry contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.