Inspection 344210554 OPENED AUG 6, 2019Closed
1544 11th St, West Linn, OR 97068 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Central Point, Oregon · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115
OSHA has inspected Frameworks Construction Inc 6 times in Oregon since 2006.
The latest one began on Aug 6, 2019 after a complaint, in West Linn.
Those inspections ended with 11 citation items: 8 serious, 1 repeat and 2 other-than-serious.
Penalties were first proposed at $6,435 and still stand at $6,435.
Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Frameworks Construction Inc averages $150 (1 cited inspection).
Want to know if OSHA cites Frameworks Construction Inc again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company1544 11th St, West Linn, OR 97068 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
351 Nw 215th Ter Bldg 1, Hillsboro, OR 97006 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR OAR 437-003-0134(8)(A) |
Serious | $150 | $150 | Mar 14, 2017 | Final |
400 Alexander Lp, Eugene, OR 97401 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $250 | $250 | Sep 5, 2013 | Closed |
8905 Nw Kearny St, Portland, OR 97229 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.1053(b)(13) · Ladders in construction |
Serious | $100 | $100 | Jun 7, 2012 | Closed |
| Citation 2, item 2 29 CFR 7031501 |
Repeat | $3,000 | $3,000 | Jun 7, 2012 | Closed |
11577 Se Lincoln Heights St, Happy Valley, OR 97086 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 7031501 |
Serious | $625 | $625 | May 17, 2011 | Closed |
| Citation 1, item 2 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $1,250 | $1,250 | May 17, 2011 | Closed |
| Citation 1, item 3 29 CFR 1926.451(b)(2)(i) · Scaffolds, general requirements |
Serious | $625 | $625 | May 17, 2011 | Closed |
| Citation 1, item 4 29 CFR 1926.28(a) · Personal protective equipment |
Serious | $310 | $310 | May 17, 2011 | Closed |
| Citation 2, item 5 | Other-than-serious | $0 | $0 | May 17, 2011 | Closed |
| Citation 2, item 6 | Other-than-serious | $0 | $0 | May 17, 2011 | Closed |
1249 Plaza Blvd, Central Point, OR 97502 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $125 | $125 | Jun 6, 2006 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(13)
(13) The top or top step of a stepladder shall not be used as a step.
29 CFR 1926.28(a)
(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.
29 CFR 1926.451(b)(2)(i)
(i) Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold shall be at least 12 inches (30 cm) wide. There is no minimum width requirement for boatswains' chairs.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.