OSHA SearchOSHA records by employer

Francisco J Muniz: OSHA inspections and violations

Arecibo, Puerto Rico · Drywall and Insulation Contractors · NAICS 238310

1inspections
3citation items
$150current penalties
Jul 15, 2015last inspection

Francisco J Muniz has one OSHA inspection on record in Puerto Rico.

OSHA opened it on Jul 15, 2015, in Arecibo.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $612 in penalties. After settlements and reviews the total is $150, down 75%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Francisco J Muniz averages $150 over 1 cited inspection in that time.

Francisco J Muniz: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

109employers cited

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch Francisco J Muniz and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340782390 OPENED JUL 15, 2015Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Oct 21, 2015

Carr#2 Km 82.1 Bo. Hato Abajo Sector San Daniel, Arecibo, PR 00612 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$204$75Sep 11, 2015Final
Citation 1, item 2
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$204$0Sep 11, 2015Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$204$75Sep 11, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.

Other drywall and insulation contractors employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.