OSHA inspectors have visited Franklin Display Group in Illinois one time.
It opened on Mar 11, 2021 on a referral, in Belvidere.
In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.
The proposed penalties came to $36,864; today they stand at $18,432, 50% less.
The rule cited most here is 1910.147 (lockout/tagout), 4 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Franklin Display Group averages $18,432 across 1 cited inspection.
Franklin Display Group also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Illinois · latest 90 days of OSHA records
421employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
Incident on Feb 26, 2021: Employee partially amputates thumb while operating press bra
At 12:45 p.m. on February 26, 2021, an employee was operating a press brake to manufacture parts. The employee's thumb became pinched between the die and the part. The employee was hospitalized to treat a partial amputation of the thumb.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Belvidere site logged 1 recordable injury or illness among about 83 workers: 1.3 per 100 full-time workers, against a median of 2.5 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Franklin Display Group
Belvidere · 2024
83
1
0
1.3
2.5
Franklin Display - Distribution Center
Belvidere · 2024
26
0
0
0.0
2.5
Franklin Display - Lincoln
Belvidere · 2023
96
1
0
1.3
2.5
Included with any plan: 3 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:
29 CFR 1910.147(c)(5)(i)
(5) Protective materials and hardware. (i) Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.