OSHA SearchOSHA records by employer

Franklin Electric Company Inc: OSHA inspections and violations

Henrico, Virginia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
10citation items
$39,010current penalties
Dec 10, 2025last inspection

Franklin Electric Company Inc has 3 OSHA inspections on record in Virginia, the first in 2016.

OSHA's last visit started on Dec 10, 2025 on a referral, in Glen Allen.

Across those inspections OSHA issued 10 citation items: 8 serious and 2 other-than-serious.

OSHA proposed $39,010 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.95, criteria for personal protective equipment (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Franklin Electric Company Inc averages $13,003 over 3 cited inspections in that time.

Franklin Electric Company Inc: OSHA citation items per year, 2016 to 2025
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Franklin Electric Company Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348634833 OPENED DEC 10, 2025Closed

Referral · Partial · Safety · 56 employees at the site · Closed Apr 30, 2026

1104 Harvest Trail Lane, Glen Allen, VA 23059 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 40.1-51.1.D.III
Other-than-serious$5,000$5,000Feb 10, 2026Final
Citation 2, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$6,885$6,885Feb 10, 2026Final
Citation 2, item 2b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Feb 10, 2026Final

Inspection 348231937 OPENED MAY 8, 2025Open

Referral · Partial · Safety · 3 employees at the site · Open

9088 Katherine Johnson Avenue, Manassas, VA 20109 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$15,875$15,875Aug 29, 2025Final
Citation 1, item 2a
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$7,940$7,940Aug 29, 2025Final
Citation 1, item 2b
29 CFR 1926.95(d)(1) · Criteria for personal protective equipment
Serious$0$0Aug 29, 2025Final

Inspection 341916674 OPENED NOV 2, 2016Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jan 16, 2017

4200 Bon Secures Pkwy, Henrico, VA 23233 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$1,155$1,155Nov 30, 2016Final
Citation 1, item 2a
29 CFR 1926.403(h) · Electrical equipment on job sites
Serious$1,155$1,155Nov 30, 2016Final
Citation 1, item 2b
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$0$0Nov 30, 2016Final
Citation 2, item 1
29 CFR 1904.33(a) · Retention and updating
Other-than-serious$1,000$1,000Nov 30, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.33 · Retention and updating

29 CFR 1904.33(a)

(a) Basic requirement. You must save the OSHA 300 Log, the privacy case list (if one exists), the annual summary, and the OSHA 301 Incident Report forms for five (5) years following the end of the calendar year that these records cover.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.150 · Fire protection

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other electrical contractors and other wiring installation contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.