OSHA SearchOSHA records by employer

Franklin Fastener Company: OSHA inspections and violations

Redford, Michigan · Other Fabricated Wire Product Manufacturing · NAICS 332618

10inspections
36citation items
$9,400current penalties
Apr 26, 2019last inspection

Franklin Fastener Company has 10 OSHA inspections on record in Michigan, the first in 1993.

OSHA's last visit started on Apr 26, 2019 after a complaint, in Redford.

Across those inspections OSHA issued 36 citation items: 23 serious and 13 other-than-serious.

OSHA proposed $18,200 in penalties. After settlements and reviews the total is $9,400, down 48%.

Most often, OSHA cited 4081.2411, (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Franklin Fastener Company averages $1,212 over 2 cited inspections in that time.

Franklin Fastener Company also files yearly injury logs with OSHA, summarized below.

Franklin Fastener Company: OSHA citation items per year, 1993 to 2019
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

641employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Franklin Fastener Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343952842 OPENED APR 26, 2019Closed

Complaint · Partial · Safety · 35 employees at the site · Closed Jun 18, 2019

12701 Beech Daly Rd, Redford, MI 48239 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343015574 OPENED MAR 21, 2018Closed

Complaint · Partial · Safety · 36 employees at the site · Closed Jul 23, 2018

12701 Beech Daly Rd, Redford, MI 48239 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Mar 2, 2018: Employee catches hand in mechanical power press and amputate

At 2:10 p.m. on March 2, 2018, an employee was making some adjustments during a production operation setup. The employee stopped a mechanical power press, removed it's guard, and reached into the die area without locking it out or installing a die block. The employee amputated two fingers on his left hand when the mechanical power press cycled. The employee was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.12461(1)
Serious$4,200$2,100Jun 20, 2018Final

Inspection 341254001 OPENED FEB 23, 2016Closed

Complaint · Partial · Safety · 24 employees at the site · Closed May 16, 2016

12701 Beech Daly Rd, Redford, MI 48239 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10121(1)
Serious$200$100Apr 27, 2016Final
Citation 1, item 2
29 CFR 408.10731(1)
Serious$200$100Apr 27, 2016Final
Citation 1, item 3
29 CFR 408.12635(1)(B)
Serious$250$125Apr 27, 2016Final
Citation 2, item 1
29 CFR 408.13308(3)
Other-than-serious$0$0Apr 27, 2016Final

Inspection 125159608 OPENED JUL 8, 2003Closed

Planned · No inspection · Health · 23 employees at the site · Closed Jul 9, 2003

12701 Beech Daly Road, Redford, MI 48239 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 127217735 OPENED JAN 31, 2000Closed

Accident · Partial · Safety · 42 employees at the site · Closed Jun 12, 2000

12701 Beech Daly Rd, Redford, MI 48239 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$700$350Apr 4, 2000Closed
Citation 1, item 2 Serious$700$350Apr 4, 2000Closed
Citation 1, item 3 Serious$700$350Apr 4, 2000Closed
Citation 1, item 4 Serious$700$350Apr 4, 2000Closed
Citation 1, item 5 Serious$700$350Apr 4, 2000Closed
Citation 1, item 6 Serious$700$350Apr 4, 2000Closed
Citation 1, item 7
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$700$350Apr 4, 2000Closed
Citation 2, item 1 Other-than-serious$0$0Apr 4, 2000Closed

Inspection 124990599 OPENED AUG 10, 1999Closed

Follow-up · Partial · Safety · 41 employees at the site · Closed Sep 1, 1999

12701 Beech Daly Rd, Redford, MI 48239 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125071753 OPENED FEB 24, 1999Closed

Planned · Complete · Safety · 41 employees at the site · Closed Sep 1, 1999

12701 Beech Daly Rd, Redford, MI 48239 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$675$338Apr 27, 1999Closed
Citation 1, item 2 Serious$675$338Apr 27, 1999Closed
Citation 1, item 3 Serious$900$450Apr 27, 1999Closed
Citation 1, item 4 Serious$900$450Apr 27, 1999Closed
Citation 1, item 5 Serious$900$450Apr 27, 1999Closed
Citation 1, item 6
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$900$450Apr 27, 1999Closed
Citation 1, item 7
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$900$450Apr 27, 1999Closed
Citation 2, item 1 Other-than-serious$0$0Apr 27, 1999Closed
Citation 2, item 2 Other-than-serious$0$0Apr 27, 1999Closed
Citation 2, item 3 Other-than-serious$0$0Apr 27, 1999Closed
Citation 2, item 4 Other-than-serious$0$0Apr 27, 1999Closed
Citation 2, item 5 Other-than-serious$0$0Apr 27, 1999Closed
Citation 2, item 6 Other-than-serious$0$0Apr 27, 1999Closed
Citation 2, item 7
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Other-than-serious$0$0Apr 27, 1999Closed
Citation 2, item 8
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Other-than-serious$0$0Apr 27, 1999Closed

Inspection 127267078 OPENED JUN 23, 1998Closed

Follow-up · Partial · Safety · 40 employees at the site · Closed Jul 9, 1998

12701 Beech Daly Rd, Redford, MI 48239 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

2 older inspections

Inspection 114865421 OPENED JUN 18, 1993Closed

Planned · Complete · Safety · 40 employees at the site · Closed Sep 8, 1993

12701 Beech Daly Rd, Redford, MI 48239 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$0$0Aug 10, 1993Closed
Citation 1, item 2 Serious$600$600Aug 10, 1993Closed
Citation 1, item 3 Serious$0$0Aug 10, 1993Closed
Citation 2, item 1 Other-than-serious$0$0Aug 10, 1993Closed
Citation 2, item 2
29 CFR 1910.1200(f)(4) · Hazard communication
Other-than-serious$0$0Aug 10, 1993Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Redford site logged 0 recordable injuries or illnesses among about 28 workers: 0.0 per 100 full-time workers, against a median of 2.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Franklin Fastener
Redford · 2025
28 000.02.7

Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(4)

(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 4081.2411

29 CFR 4081.2412

29 CFR 4081.2413

29 CFR 4081.2425

29 CFR 4081.2431

29 CFR 4081.2448

29 CFR 4081.2461

29 CFR 4081.2462

29 CFR 4081.2471

29 CFR 4081.2475

29 CFR 4081.2477

29 CFR 4081.2635

29 CFR 4081.2643

29 CFR 4081.2650

29 CFR 4081.3310

29 CFR 4081.34

29 CFR 4081.36

29 CFR 4081.645

Other other fabricated wire product manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.