Franklin Ponce: OSHA inspections and violations

Scottdale, Georgia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
3citation items
$2,640current penalties
Oct 8, 2015last inspection

Franklin Ponce has one OSHA inspection on record in Georgia.

OSHA opened it on Oct 8, 2015, in Scottdale.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $4,400 in penalties. After settlements and reviews the total is $2,640, down 40%.

Most often, OSHA cited 1926.405, job-site wiring (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Franklin Ponce averages $2,640 over 1 cited inspection in that time.

Franklin Ponce: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

146employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Franklin Ponce and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340980580 OPENED OCT 8, 2015Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Feb 28, 2017

560 Palldale Drive, Scottdale, GA 30079 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(i)(2)(i)(a) · Electrical equipment on job sites
Serious$2,800$1,680Mar 2, 2016Final
Citation 1, item 1b
29 CFR 1926.405(d) · Job-site wiring
Serious$0$0Mar 2, 2016Final
Citation 1, item 2
29 CFR 1926.405(a)(2)(ii)(c) · Job-site wiring
Serious$1,600$960Mar 2, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)(a)

(A) By location in a room, vault, or similar enclosure that is accessible only to qualified persons.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(c)

(C) Receptacles shall be of the grounding type. Unless installed in a complete metallic raceway, each branch circuit shall contain a separate equipment grounding conductor, and all receptacles shall be electrically connected to the grounding conductor. Receptacles for uses other than temporary lighting shall not be installed on branch circuits which supply temporary lighting. Receptacles shall not be connected to the same ungrounded conductor of multiwire circuits which supply temporary lighting.

29 CFR 1926.405(d)

(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.

Other electrical contractors and other wiring installation contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.