Inspection 340905322 OPENED SEP 8, 2015Closed
4500 Se Woodstock Blvd, Portland, OR 97206 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Freewire Broadband LLC has 2 OSHA inspections on record in Oregon, the first in 2015.
OSHA's last visit started on Sep 8, 2015 as a planned inspection, in Portland.
Across those inspections OSHA issued 11 citation items: 6 serious and 5 other-than-serious.
OSHA proposed $600 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.305, electrical wiring methods (4 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Freewire Broadband LLC averages $600 over 1 cited inspection in that time.
Oregon · latest 90 days of OSHA records
391employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Oregon
Checking a subcontractor, a client or your own company? Watch Freewire Broadband LLC and get notified the morning OSHA posts a new citation for it.
Watch this company4500 Se Woodstock Blvd, Portland, OR 97206 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5465 Western Ave Ste E, Beaverton, OR 97005 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $100 | $100 | Aug 10, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Serious | $100 | $100 | Aug 10, 2015 | Final |
| Citation 1, item 3 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $100 | $100 | Aug 10, 2015 | Final |
| Citation 1, item 4 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $100 | $100 | Aug 10, 2015 | Final |
| Citation 1, item 5 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $100 | $100 | Aug 10, 2015 | Final |
| Citation 1, item 6 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $100 | $100 | Aug 10, 2015 | Final |
| Citation 2, item 7 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Aug 10, 2015 | Final |
| Citation 2, item 8 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $0 | $0 | Aug 10, 2015 | Final |
| Citation 2, item 9 29 CFR OAR 437-002-0187(2)-10 |
Other-than-serious | $0 | $0 | Aug 10, 2015 | Final |
| Citation 2, item 10 29 CFR OAR 437-001-0765(1) |
Other-than-serious | $0 | $0 | Aug 10, 2015 | Final |
| Citation 2, item 11 29 CFR OAR 437-002-0041(8)(E)-4 |
Other-than-serious | $0 | $0 | Aug 10, 2015 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303(b)(2)
(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.
29 CFR 1910.303(f)(2)
(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.
29 CFR 1910.304(g)(5)
(5) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.
Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.