OSHA SearchOSHA records by employer

French Electric LLC: OSHA inspections and violations

Coleman, Texas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
8citation items
$7,020current penalties
Mar 16, 2020last inspection

French Electric LLC has 4 OSHA inspections on record in Texas, the first in 1982.

OSHA's last visit started on Mar 16, 2020 after a fatality or catastrophe, in Allen.

Across those inspections OSHA issued 8 citation items: 5 serious and 3 other-than-serious.

OSHA proposed $7,020 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.1053, ladders in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. French Electric LLC averages $6,940 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

French Electric LLC: OSHA citation items per year, 1982 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

398employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch French Electric LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344699772 OPENED MAR 16, 2020Closed

Fatality or catastrophe · Partial · Safety · 3 employees at the site · Closed Aug 19, 2020

1015 Sam Rayburn Tollway, Allen, TX 75013 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Mar 13, 2020 (fatal): Employee is killed in fall from ladder

At 12:30 p.m. on March 13, 2020, Employee #1, employed by an electrical services company, was working from a ladder at a building construction project. He was using his bare hands to connect and splice electrical wiring to the electrical panel box wiring while the wiring was energized to 120 volts. The employee fell from the ladder to the floor and then down a flight of stairs, a fall height of 24 feet. Employee #1 was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$4,048$4,048Jul 23, 2020Final
Citation 1, item 2a
29 CFR 1926.1053(b)(8) · Ladders in construction
Serious$2,892$2,892Jul 23, 2020Final
Citation 1, item 2b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Jul 23, 2020Final

Inspection 102450947 OPENED FEB 11, 1988Closed

Follow-up · Partial · Safety · 7 employees at the site · Closed Feb 11, 1988

Concho & 17th St., Coleman, TX 76236 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 102338704 OPENED OCT 29, 1987Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 24, 1988

Concho & 17th St., Coleman, TX 76834 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Dec 8, 1987Closed
Citation 1, item 2
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Other-than-serious$0$0Dec 8, 1987Closed
Citation 1, item 3
29 CFR 1926.500(e)(1)(iv) · Scope, application, and definitions applicable to this subpart
Other-than-serious$0$0Dec 8, 1987Closed

Inspection 16437360 OPENED JUN 2, 1982Closed

Planned · Complete · Safety · 3 employees at the site · Closed Feb 11, 1983

900 West Camp Wisdom, Duncanville, TX 75116 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.400(h)(1) · Introduction
Serious$80$80Jun 28, 1982Closed
Citation 1, item 1b
29 CFR 1926.401(a)(1) · [Reserved]
Serious$0$0Jun 28, 1982Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1053(b)(8)

(8) Ladders placed in any location where they can be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, shall be secured to prevent accidental displacement, or a barricade shall be used to keep the activities or traffic away from the ladder.

29 CFR 1926.400 · Introduction

29 CFR 1926.401 · [Reserved]

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(iie)

(E) All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

Other electrical contractors and other wiring installation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.